Model Number 66801496
Device Problem Pressure Problem (3012)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/25/2020
Event Type  malfunction  
Manufacturer Narrative
(b)(4).
 
Event Description
It was reported that, the vacuum motor was defective for a renasys go, it cannot generate and control negative pressure and it failed the blockage test.No patient harmed, and no injury reported because this was found during service and repair.All available information has been disclosed.If additional information should become available, a supplemental report will be submitted accordingly.
 
Manufacturer Narrative
H3, h6: the device, intended for use in treatment, has been returned and evaluated.The visual evaluation found the outer case is damaged.The functional evaluation found the device failed to generate negative pressure, establishing a relationship with the reported event.The root cause is a defective vacuum pump.A review of the associated batch manufacturing records confirmed that the device met manufacturing specifications at the point of release.The complaint history review found further instances of the reported event.This investigation is now complete with no further action deemed necessary.We will continue to monitor for any adverse trends relating to this product range.Smith + nephew acknowledge customer concern and are continually investigating ways to develop and improve our products.
 
Event Description
It was reported that the renasys go device cannot generate and control negative pressure and it failed the blockage test.No patient involved, found during service and repair.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RENASYS GO
Type of Device
NEGATIVE PRESSURE WOUND THERAPY POWERED SUCTION PUMP
Manufacturer (Section D)
SMITH & NEPHEW MEDICAL LTD.
101 hessle road
hull east riding of yorkshire HU3 2 BN
UK  HU3 2BN
MDR Report Key11021010
MDR Text Key221833707
Report Number8043484-2020-04281
Device Sequence Number1
Product Code OMP
UDI-Device Identifier00040565126944
UDI-Public00040565126944
Combination Product (y/n)N
PMA/PMN Number
K152163
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 04/19/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/16/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number66801496
Device Catalogue Number66801496
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/16/2021
Date Manufacturer Received03/26/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-