Model Number DBP-EX-150SOL145
Device Problem Entrapment of Device (1212)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/07/2020
Event Type  malfunction  
Manufacturer Narrative
The results of the investigation are inconclusive since the reported device was not returned for analysis. Based on the information received, the cause of the reported event could not be conclusively determined. The device history record for this oad lot number has been reviewed. No issues or discrepancies were noted during this review that would have contributed to the reported event. The device met material, assembly, and quality control requirements. Csi id:(b)(4).
 
Event Description
During orbital atherectomy treatment on a lesion in the popliteal artery, the peripheral exchangeable orbital atherectomy device (oad) stalled and stopped spinning. The oas pump light was observed to be yellow and all connections were found to be secure. The pump was powered on and all leds on the oad handle were illuminated, so the device was removed. During device removal the oad was unable to move backward on the guide wire and both the wire and device were removed from the patient. The lesion was re-wired and the procedure was completed with a second oad. Due to the time required to remove the device and re-wire the lesion, a delay of 30 minutes or greater occurred. There were no patient adverse events.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameDIAMONDBACK 360 PERIPHERAL ORBITAL ATHERECTOMY SYSTEM
Type of DevicePERIPHERAL ATHERECTOMY DEVICE
Manufacturer (Section D)
CARDIOVASCULAR SYSTEMS, INC.
1225 old highway 8 nw
saint paul MN 55112
Manufacturer (Section G)
CARDIOVASCULAR SYSTEMS, INC.
1225 old highway 8 nw
saint paul MN 55112
Manufacturer Contact
brittany leider
1225 old highway 8 nw
saint paul, MN 55112
6512591600
MDR Report Key11069244
MDR Text Key224596114
Report Number3004742232-2020-00418
Device Sequence Number1
Product Code MCW
UDI-Device Identifier10852528005831
UDI-Public(01)10852528005831(17)220930(10)34678
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K190634
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation
Type of Report Initial
Report Date 12/23/2020
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received12/23/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date09/30/2022
Device Model NumberDBP-EX-150SOL145
Device Catalogue Number7-10030-03
Device Lot Number346478
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received12/07/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured09/24/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-