Model Number 22437-19
Device Problem Material Separation (1562)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/08/2020
Event Type  malfunction  
Manufacturer Narrative
The device has been received.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.
 
Event Description
It was reported that while advancing the emboshield nav 6 filter over the barewire, so that it could be delivered to the lesion using the delivery catheter, the distal tip of the delivery catheter separated.The filter never entered the patient.A new filter was prepped.Deployed, and recovered successfully to complete the procedure.There were no reported adverse patient effects and no clinically significant delay in the procedure.No additional information was provided.
 
Manufacturer Narrative
The device was returned for analysis.The reported separation was confirmed.Additionally, a tear was noted on the pod.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no other similar incidents reported from this lot.The investigation determined that the pod separation was due to inadvertent mishandling.Based on the reported information, it appears that the pod of the delivery catheter was inadvertently handled while attempting to exchange the short barewire (190 cm) to a long barewire (315 cm) causing the pod to separate.The noted tear is likely due to procedural circumstances.There is no indication of a product quality issue with respect to the design, manufacture, or labeling of the device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EMBOSHIELD NAV6 EMBOLIC PROTECTION SYSTEM
Type of Device
EMBOLIC PROTECTION SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
MDR Report Key11089821
MDR Text Key225807313
Report Number2024168-2020-10978
Device Sequence Number1
Product Code NTE
UDI-Device Identifier08717648137747
UDI-Public08717648137747
Combination Product (y/n)N
PMA/PMN Number
K141678
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 01/13/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/29/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date06/30/2023
Device Model Number22437-19
Device Catalogue Number22437-19
Device Lot Number007276A
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/16/2020
Date Manufacturer Received01/08/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-