Catalog Number 8065750469
Device Problems Overheating of Device (1437); Failure to Power Up (1476)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/01/2020
Event Type  malfunction  
Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.(b)(4).
 
Event Description
A nurse reported that during a cataract extraction procedure the phacoemulsification (phaco) handpiece got hot and had no power.Additional information has been requested and received which indicated.There was no system message displayed.The handpiece was exchanged and the procedure was completed with no impact to the patient.
 
Manufacturer Narrative
Additional information has been provided in d.4., d.9., h.3., h.6.And h.10.Corrected information has been provided in h.6.Patient code.The phaco handpiece was received and a visual assessment of the returned sample found no nonconformities.The returned phaco handpiece was connected to a calibrated system.The phaco handpiece tuned successfully and completed a five-minute burn in test with the system set at 100% ultrasonic and torsional power.The temperature of the phaco handpiece shell was measured and was found to meet specifications.The phaco handpiece was connected to dynamic tuning fixture (dtf) for stroke length testing on the longitudinal and torsional movements, which found the torsional stroke measurement of the phaco handpiece did not meet product specifications.Disassembling the handpiece revealed moisture ingress within the electrode chamber.There was no problem found with the returned phaco handpiece during testing, as related to the reported event of the handpiece getting hot.The reported event of no phaco power was confirmed through dtf testing which found the phaco handpiece did not meet specifications for the torsional stroke measurement.Disassembling the phaco handpiece revealed moisture ingress within the electrode chamber, however, how or when the moisture entered the phaco handpiece remains inconclusive.The phaco handpiece manufacturing device history record (dhr) was reviewed.Based on qa assessment, the product met specifications at the time of release.The returned handpiece was found to exhibit no problems as related to the reported event of the handpiece getting hot; therefore, the root cause of the reported event cannot be determined conclusively.The root cause of the reported event of no phaco power can be attributed to moisture ingress causing a short circuit from the high electrode to ground; however, how or when moisture entered the handpiece remains inconclusive.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INFINITI VISION SYSTEM, ACCESSORY, OZIL TORSIONAL HANDPIECE
Type of Device
UNIT, PHACOFRAGMENTATION
Manufacturer (Section D)
ALCON RESEARCH, LLC - IRVINE TECHNOLOGY CENTER
15800 alton parkway
irvine CA 92618
MDR Report Key11103549
MDR Text Key225816384
Report Number2028159-2021-00001
Device Sequence Number1
Product Code HQC
Combination Product (y/n)N
PMA/PMN Number
K112425
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Type of Report Initial,Followup
Report Date 05/03/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/01/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number8065750469
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/05/2021
Date Manufacturer Received04/23/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-