Model Number 1217-32-056
Device Problem Naturally Worn (2988)
Patient Problem Insufficient Information (4580)
Event Date 01/04/2021
Event Type  Injury  
Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
It was reported that the constrained liner broke, cup locking mechanism was worn and needed to be replaced.Cup was removed and replaced with a multi-hole cup and pinnacle dual mobility.Original surgery for the cup and screws was done (b)(6) 2013, head was done (b)(6) 2020 at the first hip rev(pt fell and folded over the lip on his liner) and constrained liner was done (b)(6) 2020 (he dislocated from his previous rev).No surgical delay.Doi: (b)(6) 2013 (cup, screws), doi: (b)(6) 2020 (head and liner), dor: (b)(6) 2021, right hip.
 
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed, and the investigation will be re-opened as necessary.Device history lot : a search of the depuy nonconformance (nc) quality system found no nc¿s associated with this product/lot combination.Device history review : a search of the depuy nonconformance (nc) quality system found no nc¿s associated with this product/lot combination.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PINN SECTOR W/GRIPTION 56MM
Type of Device
PINNACLE HIP SYSTEM : HIP METAL ACETABULAR CUPS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key11207320
MDR Text Key227950216
Report Number1818910-2021-01600
Device Sequence Number1
Product Code KWA
UDI-Device Identifier10603295010326
UDI-Public10603295010326
Combination Product (y/n)N
PMA/PMN Number
K093646
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 01/04/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/21/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number1217-32-056
Device Catalogue Number121732056
Device Lot Number347998
Was Device Available for Evaluation? No
Date Manufacturer Received02/11/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
ARTICULEZE M HEAD 36MM +5; PINN CAN BONE SCREW 6.5MMX20MM; PINN CAN BONE SCREW 6.5MMX25MM; PINN LNR CON +4 10D 36IDX56OD; SUMMIT POR TAPER SZ7 HI OFF; ARTICULEZE M HEAD 36MM +5; PINN CAN BONE SCREW 6.5MMX20MM; PINN CAN BONE SCREW 6.5MMX25MM; PINN LNR CON +4 10D 36IDX56OD; SUMMIT POR TAPER SZ7 HI OFF
Patient Outcome(s) Required Intervention;
Patient Age73 YR
-
-