MAUDE Adverse Event Report: MAQUET CARDIOPULMONARY GMBH HEART LUNG MACHINE; PUMP, BLOOD, CARDIOPULMONARY BYPASS, NON-ROLLER TYPE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MAQUET CARDIOPULMONARY GMBH HEART LUNG MACHINE; PUMP, BLOOD, CARDIOPULMONARY BYPASS, NON-ROLLER TYPE Back to Search Results
Model Number ROTAFLOW
Device Problem Electrical /Electronic Property Problem (1198)
Patient Problems No Patient Involvement (2645); No Known Impact Or Consequence To Patient (2692)
Event Date 11/24/2020
Event Type  malfunction  
Manufacturer Narrative
A follow-up medwatch will be submitted when additional information becomes available.
 
Event Description
Initial failure description received on (b)(6) 2020: control board mal.Service order received on (b)(6) 2021 (adverse event date (b)(6) 2021): it was reported that the rotaflow displays the error message ¿head error¿ when reaching 2000 revolutions per minute.Complaint id: (b)(4).
 
Manufacturer Narrative
The reported "head error" occurred when no patient has been involved.The device was directly involved in the event.A getinge service technician was onsite on 2021-02-02 to repair the affected rotaflow.The 70103.4051 rfc control board kit has been replaced.After replacement is the rotaflow working as inteded again.The following most possible root cause could be determined for the head error: the head error is caused by the hot plug.When the device is in operation and the power plug is plugged in or out the head error occurs and the rota flow drive and / or the control board is damaged.As a result the rota flow drive and / or the control board has to be replaced.A device history review (dhr) was performed and the dhr does not show any abnormality or issue that is related or can have led to the customer complaint.Based on these investigation results the reported failure could be confirmed.In order to avoid reoccurrence of the reported failure, the user will be informed to follow the chapter in the instruction for use heart-lung support system rotaflow system| 4.2 | en | v13.Chapter 4.1.3: switch off the rotaflow console on/off switch before connecting the rotaflow drive to or disconnecting it from the rotaflow console.Otherwise the rotaflow console may be damaged.The occurrence rate was calculated for the reported issue and it was determined that this is not a systemic issue.Therefore, no remedial action is required the occurrence rate related to the reported issue is currently being monitored as part of maquet cardiopulmonary¿s trending program and additional investigations or corrections will be implemented in case of adverse trending.
 
Event Description
Complaint id: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HEART LUNG MACHINE
Type of Device
PUMP, BLOOD, CARDIOPULMONARY BYPASS, NON-ROLLER TYPE
Manufacturer (Section D)
MAQUET CARDIOPULMONARY GMBH
neue rottenburger strasse 37
hechingen
MDR Report Key11313189
MDR Text Key231318159
Report Number8010762-2021-00111
Device Sequence Number1
Product Code KFM
Combination Product (y/n)N
PMA/PMN Number
K991864
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,foreign,health profe
Type of Report Initial,Followup
Report Date 02/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/11/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberROTAFLOW
Device Catalogue Number70104.3299
Was Device Available for Evaluation? Yes
Date Manufacturer Received02/19/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-