Model Number 0684-00-0480-01
Device Problems Off-Label Use (1494); Material Deformation (2976)
Patient Problems No Consequences Or Impact To Patient (2199); No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Manufacturer Narrative
Event site postal code: (b)(6).The device was not returned and could not be evaluated.It was discarded by the user.We are unable to confirm the reported event.If new information becomes available, a supplemental report will be submitted.Complaint record id #: (b)(4).
 
Event Description
It was reported that during intra-aortic balloon (iab) therapy, the iab was attached the patient's chest leaving a "c"-shaped loop in the iab which bends and kinks and blocks a lot of patient movement.The insertion was reported to be axillary, which is not the method described in the device instructions for use.This is the fourth iab the customer has had this issue with during this event.There was no patient harm or adverse event reported.This report is for the third iab used in this event.Separate reports will be sent for the first, second, and fourth iabs used.
 
Manufacturer Narrative
The device has not been returned to the manufacturer so we are unable to complete an evaluation.If provided we will send a supplemental report with our additional findings.The device history records review concluded that there were no ncmrs, rework, or deviations documented for the reported lot/serial number.Based on the dhr/lhr review results, it was determined that there is no relation between the manufacturing process and the reported failure.The review of the historical data indicates that no other similar complaint was reported for the same lot/serial number and reported failure mode.The overall 24 month product complaint trend data for the period (b)(6) through (b)(6) was reviewed.There were no triggers identified for the review period.Communication/interviews were performed to obtain all possible information.Reference complaint #(b)(4).H3 other text: device not returned.
 
Event Description
It was reported that during intra-aortic balloon (iab) therapy, the iab was attached the patient's chest leaving a "c"-shaped loop in the iab which bends and kinks and blocks a lot of patient movement.The insertion was reported to be axillary, which is not the method described in the device instructions for use.This is the fourth iab the customer has had this issue with during this event.There was no patient harm or adverse event reported.This report is for the third iab used in this event.Separate reports will be sent for the first, second, and fourth iabs used.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LINEAR 7.5 FR. 40CC IAB
Type of Device
SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL
Manufacturer (Section D)
DATASCOPE CORP. - FAIRFIELD
15 law drive
fairfield NJ 07004
MDR Report Key11366630
MDR Text Key233102675
Report Number2248146-2021-00119
Device Sequence Number1
Product Code DSP
UDI-Device Identifier10607567106564
UDI-Public10607567106564
Combination Product (y/n)N
PMA/PMN Number
K041281
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 06/23/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/23/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number0684-00-0480-01
Device Catalogue Number0684-00-0475
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Date Manufacturer Received06/23/2021
Is This a Reprocessed and Reused Single-Use Device? No