Catalog Number NCEUP3520X
Device Problem Detachment of Device or Device Component (2907)
Patient Problem Unspecified Tissue Injury (4559)
Event Date 02/22/2021
Event Type  Injury  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
During a procedure an attempt was made to use one nc euphora rx ptca balloon catheter to treat a mildly tortuous, moderately calcified lesion exhibiting 95% stenosis located in the mid circumflex (cx) artery. The device was inspected with no issues noted. Negative prep was performed with no issues noted. The lesion was pre-dilated. The device did pass through a previously deployed stent. Resistance was not encountered when advancing the device. Excessive force was not used during delivery. It was reported that the catheter detached during removal of the device. It was stated that the detached portion remained in the patient. It was stated that most of the detached portion of the balloon catheter was inside the guide catheter. A balloon was inserted inside the guide catheter and inflated to trap the detached catheter against the guide catheter wall. The detached shaft was safely removed from patient. The patient was reported to be alive with no further injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameNC EUPHORA RX
Type of DeviceCATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
MEDTRONIC MEXICO
av. paseo del cucapah #10510
tijuana,bc 22570
MX 22570
Manufacturer (Section G)
MEDTRONIC MEXICO
av. paseo del cucapah #10510
tijuana,bc 22570
MX 22570
Manufacturer Contact
toni o'doherty
parkmore business park west
galway 
EI  
091708734
MDR Report Key11403344
MDR Text Key234391139
Report Number9612164-2021-00841
Device Sequence Number1
Product Code LOX
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K141090
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation
Type of Report Initial,Followup,Followup
Report Date 04/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/03/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator
Device Catalogue NumberNCEUP3520X
Device Lot Number221033260
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received04/22/2021
Was Device Evaluated by Manufacturer? No Answer Provided
Date Device Manufactured10/23/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 03/03/2021 Patient Sequence Number: 1
-
-