|
Model Number 1DLMC05 |
Device Problem
Insufficient Information (3190)
|
Patient Problems
Unspecified Infection (1930); Tissue Breakdown (2681); Insufficient Information (4580)
|
Event Date 09/02/2016 |
Event Type
Injury
|
Manufacturer Narrative
|
The plus antimicrobial product coating contains silver carbonate [approximately 800 micrograms per cubic centimeter of product (g/cm3)], and chlorhexidine diacetate [approximately 1600 micrograms per cubic centimeter of product (g/cm3)].It should be noted that the gore® dualmesh® plus biomaterial instructions for use addresses the following adverse reactions among others: ¿possible adverse reactions with the use of any tissue deficiency prosthesis may include, but are not limited to, contamination, infection, inflammation, adhesion, fistula formation, seroma formation, hematoma, and recurrence". the gore® dualmesh® plus biomaterial instructions for use also states: ¿strict aseptic techniques should be followed.If an infection develops, it should be treated aggressively.An unresolved infection may require removal of the material".
|
|
Event Description
|
It was reported to gore that the patient underwent open incisional hernia repair on (b)(6) 2006 whereby a gore® dualmesh® plus biomaterial was implanted.The complaint alleges that on (b)(6) 2013 an additional procedure occurred whereby the gore device was explanted.It was reported the patient alleges the following injuries: chronically draining granuloma, with excision of the umbilical granuloma and debridement of mesh material, infection of the mesh, dense adhesive changes around the base of the umbilicus, exposed mesh, explantation of mesh, recurrent hernia, sinus tract from skin to the mesh with some portion of the mesh not incorporating into the abdominal wall and with evidence of chronic infection.Additional event specific information was not provided.
|
|
Manufacturer Narrative
|
H6: updated results code.Conclusion code remains unchanged.It should be noted that the gore® dualmesh® biomaterial instructions for use addresses the following adverse reactions among others: ¿possible adverse reactions with the use of any tissue deficiency prosthesis may include, but are not limited to, contamination, infection, inflammation, adhesion, fistula formation, seroma formation, hematoma, and recurrence.The gore® dualmesh® biomaterial instructions for use also states: ¿strict aseptic techniques should be followed.If an infection develops, it should be treated aggressively.An unresolved infection may require removal of the material.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any "defects" or has "malfunctioned".These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
|
Manufacturer Narrative
|
B7: added medical history.H6: conclusion code remains unchanged.H10/11: added medical record information.Additional details regarding the patient's clinical course were ascertained from a review of medical records and are as follows: revision preoperative complaints: on (b)(6) 2016: (b)(6) medical center.(b)(6).History and physical.Chief complaint: ¿umb [umbilical mass].¿ history: ¿patient has noticed some irritated tissue at the base of her umbilicus for several years.In the last several months it has become worse with significant drainage and what appeared to be suture material.She denies any other abdominal or digestive symptoms.She denies any fevers or chills currently.She did have a hernia repair at the site after a laparoscopy.¿ physical exam: ¿abdomen: soft.There is a 2 cm area of granulation tissue at the base of the umbilicus with some serous type drainage.¿ impression/plan: ¿umbilical granuloma possible suture abscess.We¿ll plan on exploration and revisions in the or with mac [monitored anesthesia care] anesthesia at the next available time.¿ revision procedure: excision of umbilical granuloma and debridement of suture and mesh material.Revision date: (b)(6) 2016 [same day surgery] on (b)(6) 2016: (b)(6) medical center.(b)(6).Operative report.Pre and postoperative diagnosis: a chronically draining umbilical granuloma.Anesthesia: monitored anesthesia care [mac].Findings: ¿at the base of the umbilicus there [sic] prolene sutures as well as ethibond sutures and a corner of mesh.There was not active purulence around this but appeared that may have been an isolated infection of the mesh.This was debrided back to healthy-appearing tissue and closed after washing out the incision.¿ procedure: ¿the patient was taken to the procedure room after informed consent.The previous subinfraumbilical incision was reopened down to the fascia.There were dense adhesive changes around the base of the umbilicus.This was debrided and encircled with a clamp.At this point, prolene sutures as well as ethibond sutures and a corner of mesh were exposed.These were debrided as far to the left lateral position as possible.There was some bleeding that was controlled with cautery.Extensive irrigation was then performed.There did not appear to be any significant inflammation or purulence left at this point.A 3-0 vicryl was used to close the umbilical defect and tack it to the fascia.The incision was then closed with running 4-0 monocryl.Steri-strips were then applied, and the patient was discharged to recovery in good condition.¿ a potential relationship, if any, between the alleged injuries or complications and the gore device has not been established at this time based on available information.It should be noted that the gore® dualmesh® biomaterial instructions for use addresses the following adverse reactions among others: ¿possible adverse reactions with the use of any tissue deficiency prosthesis may include, but are not limited to, contamination, infection, inflammation, adhesion, fistula formation, seroma formation, hematoma, and recurrence.The gore® dualmesh® biomaterial instructions for use also states: ¿strict aseptic techniques should be followed.If an infection develops, it should be treated aggressively.An unresolved infection may require removal of the material.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any "defects" or has "malfunctioned".These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
|
Manufacturer Narrative
|
The investigation has been completed.Based upon the totality of the information received over the course of the investigation and reported by gore in the previously submitted medical record narratives the following conclusions have been reached.As previously reported, all pertinent medical records requested may not have been received.No further investigation is required at this time.Based upon gore¿s investigation there is no available information that reasonably suggests that a gore device may have caused or contributed to death, serious injury or reportable malfunction, and is no longer considered reportable.Therefore, this event is being coded as insufficient information and no findings available and will be closed as ¿cause not established¿.Previous patient codes were reported based on the original complaint and are no longer applicable and/or not reportable per gore¿s investigation.Following gore¿s investigation, the previously submitted annex f code has been updated to reflect gore¿s final conclusion.It should be noted that the gore® dualmesh® biomaterial instructions for use include warnings and addresses the following adverse reactions among others: ¿possible adverse reactions with the use of any tissue deficiency prosthesis may include, but are not limited to, contamination, infection, inflammation, adhesion, fistula formation, seroma formation, hematoma, and recurrence.¿ the instructions for use further states: ¿if gore® dualmesh® biomaterial is cut too small, excessive tension may be placed on the suture line, which may result in recurrence of the original, or development of an adjacent, tissue defect.¿ the instructions for use further warn: ¿strict aseptic techniques should be followed.If an infection develops, it should be treated aggressively.An unresolved infection may require removal of the material.¿ procedure and specific patient factors may contribute to or cause infection, leading to contamination, exposure, lack of incorporation and/or seeding of device.Procedure related factors may include adherence to clinical guidelines on infection risk management, contamination of device prior to or during implant, and post-operative persistent/symptomatic seroma and wound management.Patient risk factors may include diabetes, smoking, age, malnutrition, immunosuppressive therapy, post-operative instruction noncompliance, and hygiene.Individual medical decisions, if inconsistent and/or non-conforming to the device manufacturer¿s recommendations, ifu, or recognized best practices, may result in or contribute to an adverse event.There is insufficient information available for gore to reasonably draw conclusions related to aspects of the event, therefore conclusion code ¿d15: cause not established¿ is being used.Insufficient information may include limited or missing relevant medical records, involvement of multiple implanted devices (including non-gore devices) in the field of treatment, patient non-compliance, and/or a general lack of available detail or specificity related to an adverse event and/or device.As with any surgical procedure, there are always risks of complications for surgical repair of hernias and soft tissue deficiencies, with or without mesh.¿these may include but are not limited to, adhesions and related harms, bleeding, bowel obstruction, compromised device biocompatibility, contamination which may lead to patient harms, device damage, dysphagia, erosion or extrusion and related harms, exposure or protrusion and related harms, fever, fistula, gerd recurrence, defect recurrence and related harms, ileus, increased procedure time and related harms, irritation or inflammation, infection, mesh migration, mesh contraction, pain, paresthesia, perforation, revision/re-intervention, seroma or hematoma and related harms, tissue ischemia, wound complications and wound dehiscence and additional intervention including surgery.Many of the potential complications are associated with the patient¿s underlying disease progression, co-morbidities, additional medical history and/or other surgical procedures.¿the above inherent risks are typically detailed in standard informed consent documents.¿ the device was not able to be returned to gore for evaluation; therefore, a direct product analysis could not be conducted.Review of the manufacturing and sterilization records verified that the lot met all pre-release specifications.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any "defects" or has "malfunctioned".These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
|
Search Alerts/Recalls
|
|
|