Patient identifier not available from the site.Patient age is the mean value of patients in the study.Patient gender is the majority value of patients in the study.Patient weight not available from the site.Event date is the accepted date of the publication.Device lot number, or serial number, unavailable.No parts have been received by the manufacturer for evaluation.Device manufacturing date is dependent on lot number/serial number, therefore, unavailable.If information is provided in the future, a supplemental report will be issued.
|
Citation: matteo zoli, lia talozzi, matteo martinoni, david n.Manners, filippo badaloni, claudia testa, sofia asioli, micaela mitolo, fiorina bartiromo, magali jane rochat, viscardo paolo fabbri, carmelo sturiale, alfredo conti, raffaele lodi, diego mazzatenta, and caterina tonon.From neurosurgical planning to histopathological brain tumor characterization: potentialities of arcuate fasciculus along-tract diffusion tensor imaging tractography measures.Frontiers in neurology.12:633209.Doi: 10.3389/fneur.2021.633209 abstract: background: tractography has been widely adopted to improve brain gliomas¿ surgical planning and guide their resection.This study aimed to evaluate state-of-the-art of arcuate fasciculus (af) tractography for surgical planning and explore the role of along-tract analyses in vivo for characterizing tumor histopathology.Methods: high angular resolution diffusion imaging (hardi) images were acquired for nine patients with tumors located in or near language areas (age: 41 ± 14 years, mean ± standard deviation; five males) and 32 healthy volunteers (age: 39 ± 16 years; 16 males).Phonemic fluency task fmri was acquired preoperatively for patients.Af tractography was performed using constrained spherical deconvolution diffusivity modeling and probabilistic fiber tracking.Along-tract analyses were performed, dividing the af into 15 segments along the length of the tract defined using the laplacian operator.For each af segment, diffusion tensor imaging (dti) measures were compared with those obtained in healthy controls (hcs).The hemispheric laterality index (li) was calculated from language task fmri activations in the frontal, parietal, and temporal lobe parcellations.Tumors were grouped into low/high grade (lg/hg).Results: four tumors were lg gliomas (one dysembryoplastic neuroepithelial tumor and three glioma grade ii) and five hg gliomas (two grade iii and three grade iv).For lg tumors, gross total removal was achieved in all but one case, for hg in two patients.Tractography identified the af trajectory in all cases.Four along-tract dti measures potentially discriminated lg and hg tumor patients (false discovery rate= 0.1): the number of abnormal md and rd segments, median ad, and md measures.Both a higher number of abnormal af segments and a higher ad and md measures were associated with hg tumor patients.Moreover, correlations (unadjusted p = 0.05) were found between the parietal lobe li and the dti measures, which discriminated between lg and hg tumor patients.In particular, a more rightward parietal lobe activation (li = 0) correlated with a higher number of abnormal md segments (r = -0.732) and rd segments (r = -0.724).Conclusions: af tractography allows to detect the course of the tract, favoring the safer-as-possible tumor resection.Our preliminary study shows that along-tract dti metrics can provide useful information for differentiating lg and hg tumors during pre-surgical tumor characterization.Reported events: one patient experienced a case of epileptic seizures, which were controlled by antiepileptic drugs.One patient experienced a post-operative transit aphasia and one semantic paraphasia which recovered after 30 and 2 days respectively.
|