Catalog Number 121731048
Device Problems Device Dislodged or Dislocated (2923); Noise, Audible (3273)
Patient Problems Pain (1994); Synovitis (2094); Discomfort (2330); Joint Laxity (4526); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Date 03/24/2021
Event Type  Injury  
Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Revision procedure for patient experiencing pain.Xray revealed worn polyethylene liner.Operative notes indicated discomfort, loud squeaking, polyethyline fracture, fractured worn polyethyline with subluxation out of the ring fixation, wear debris and synovitis.Provided x-ray image and explanted device photographs confirms a rim fracture of the poly liner.Review of the x-ray and the femoral head photo finds sufficient evidence of a disassociation event.Doi: unknown; dor: (b)(6) 2021; left hip.
 
Manufacturer Narrative
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: added: d4 (lot #, udi), d6a, d9, d10, g4 and h4.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Corrected: d1, d2a, d2b and d4 (catalog).
 
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.Visual examination of the provided x-ray image found evidence of disassociation.A worldwide complaint database search found no other related reported incidents against the provided product code/lot number combination since release for distribution.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Device history lot : the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).Where the lot code was provided, a manufacturing records evaluation (mre) was not performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PINN 100 W/GRIPTION 48MM
Type of Device
PINNACLE HIP SYSTEM : HIP METAL ACETABULAR CUPS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key11685922
MDR Text Key246046310
Report Number1818910-2021-08187
Device Sequence Number1
Product Code KWA
Combination Product (y/n)N
PMA/PMN Number
K090998
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup,Followup
Report Date 04/13/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/19/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number121731048
Device Lot Number710253
Was Device Available for Evaluation? No
Date Manufacturer Received06/24/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
ALTRX NEUT 32IDX48OD; APEX HOLE ELIM POSITIVE STOP; CORAIL AMT COLLAR SIZE 11; DELTA CER HEAD 12/14 32MM +1; ALTRX NEUT 32IDX48OD; DELTA CER HEAD 12/14 32MM +1
Patient Outcome(s) Required Intervention;
Patient Age76 YR
-
-