ABBOTT VASCULAR G4 STEERABLE GUIDING CATHETER CATHETER, STEERABLE Back to Search Results
Catalog Number SGC0702
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Perforation (2001)
Event Date 03/29/2021
Event Type  Injury  
Manufacturer Narrative
The device will not be returned for evaluation, the device was reportedly discarded. Investigation is not yet complete. A follow-up report will be submitted with all additional relevant information.
 
Event Description
This is filed to report a perforation. It was reported this was a mitraclip procedure to treat functional mitral regurgitation (mr) with a grade of 4. Prior to inserting the devices, it was noted the patient had an enlarged atrium. Two clips were successfully implanted, reducing mr to a grade of less than 1. However, after removing the steerable guide catheter (sgc), a left to right shunt was observed. To treat the shunt an occluder was implanted. There was no clinically significant delay in the procedure. No additional information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameG4 STEERABLE GUIDING CATHETER
Type of DeviceCATHETER, STEERABLE
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005070406
3885 bohannon drive
menlo park CA 94025
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key11694343
MDR Text Key246283128
Report Number2024168-2021-03300
Device Sequence Number1
Product Code DRA
Combination Product (y/n)N
Reporter Country CodeGM
PMA/PMN Number
K190167
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation
Type of Report Initial,Followup
Report Date 05/28/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/20/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Expiration Date10/26/2021
Device Catalogue NumberSGC0702
Device Lot Number01027U128
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received05/07/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured10/27/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 04/20/2021 Patient Sequence Number: 1
Treatment
IMPLANTED MITRACLIP (X2)
-
-