Catalog Number 466P306X |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Perforation (2001); Perforation of Vessels (2135)
|
Event Date 08/20/2020 |
Event Type
Injury
|
Manufacturer Narrative
|
Reporter occupation: other, senior counsel, litigation.Please note that the exact event date is unknown and the event date is the complaint awareness date.As reported, the patient underwent placement of an trapease inferior vena cava (ivc) filter.The indication for filter placement is not available.The report states that the filter subsequently malfunctioned and caused injury and damage to the patient including, but not limited to perforation.The filter remains implanted; thus, unavailable for analysis.The product was not returned for analysis and the sterile lot number has not been provided; therefore, no device analysis nor device history record review could be performed.The trapease vena cava filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the vena cava for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pulmonary embolism where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pulmonary embolism where anticoagulant therapy has failed, or is contraindicated.The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart.It was reported that there was perforation of the ivc; however, a clinical conclusion could not be determined as to the cause of the event.A review of the instructions for use notes vessel damage such as intimal tears and perforation as procedural complications related it ivc filters.Ivc perforation from removable filters is relatively common, and directly related to how long the filter has been in place.Studies have noted a greater than 80% perforation rate overall, with all filters imaged after 71 days from implantation revealing some level of perforation.Clinical factors that may have influenced the event include patient, pharmacological and lesion characteristics.Without procedural films or images for review the reported event(s) could not be confirmed.Given the limited information available for review at this time, there is nothing to suggest that the reported events are related to the design and manufacturing process of the device; therefore, no corrective action will be taken.Should additional information become available, the file will be updated accordingly.Please note that this is the initial report for this product.
|
|
Event Description
|
As reported by the legal brief, the patient underwent placement of an trapease vena cava filter.The report states that the filter subsequently malfunctioned and caused injury and damage to the patient including, but not limited to perforation.As a direct and proximate result of these malfunctions, the patient suffered life-threatening injuries and damages, and required extensive medical care and treatment.As a further proximate result, the patient has suffered and will continue to suffer significant medical expenses, pain and suffering, and other damages.
|
|
Manufacturer Narrative
|
As reported, the patient underwent placement of an trapease inferior vena cava (ivc) filter.Per the medical records, the indication was pe (pulmonary embolus), s/p trauma with surgical intervention and multiple fractures.A venocavogram located the renal veins and assessed the caliber of the ivc.The filter was successfully deployed in an infrarenal position.There were no reports of complications.The report states that the filter malfunctioned including ivc perforation.Per the patient profile form (ppf), the patient experienced perforation of filter struts outside the ivc, along with back pain, stress and anxiety.The product was not returned for analysis and the sterile lot number has not been provided; therefore, no device analysis nor device history record review could be performed the trapease vena cava filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the vena cava for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pulmonary embolism where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pulmonary embolism where anticoagulant therapy has failed, or is contraindicated.The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart.It was reported that there was perforation of the ivc; however, a clinical conclusion could not be determined as to the cause of the event.A review of the instructions for use notes vessel damage such as intimal tears and perforation as procedural complications related it ivc filters.Ivc perforation from removable filters is relatively common, and directly related to how long the filter has been in place.Studies have noted a greater than 80% perforation rate overall, with all filters imaged after 71 days from implantation revealing some level of perforation.Anxiety and pain do not represent a device malfunction and may be related to underlying patient related issues.Clinical factors that may have influenced the event include patient, pharmacological and lesion characteristics.Without procedural films or images for review the reported event(s) could not be confirmed.Given the limited information available for review at this time, there is nothing to suggest that the reported events are related to the design and manufacturing process of the device; therefore, no corrective action will be taken.Should additional information become available, the file will be updated accordingly.Style= "color: rgb (32, 23, 205); margin: 0 in"; corrected data: style= "color: rgb (32, 23, 205); margin: 0 in".Section d6a: the correct implant date was (b)(6) 2003.
|
|
Event Description
|
Additional information received per the medical records indicate that the patient had a history of recent surgery, trauma, multiple fractures and pulmonary embolus.The filter was deployed via the patient's right side common femoral vein.There were no complications. additional information received per the patient profile form (ppf) states that the patient experienced perforation of filter struts outside the inferior vena cava (ivc).The patient became aware of the reported event approximately sixteen years and nine months after the index procedure.The patient also experienced back pain, stress and anxiety.
|
|