Model Number 10622
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Hypersensitivity/Allergic reaction (1907); Rash (2033)
Event Date 03/03/2021
Event Type  Injury  
Event Description
(b)(6) registry. It was reported that patient experienced allergic eruption. In (b)(6) 2020, the subject was referred for cardiac catheterization and index procedure was performed on the same day. The target lesion was located in the mid left anterior descending artery (lad) extending up-to distal lad with 85% stenosis and was 30mm long, with a reference vessel diameter of 3. 00mm. The target lesion was treated with pre-dilatation and placement of 2. 75 mm x 32 mm synergy stent system and post-dilatation was performed with residual stenosis as 0%. Two days after, the subject was discharged on aspirin and clopidogrel. In (b)(6) 2021, the subject was noted with allergic eruption and was hospitalized on the same day for further evaluation and treatment. The event was treated medically and no other action was taken to treat the event. Five days later, the event was considered to be recovered/resolved and the subject was discharged on the same day.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameSYNERGY
Type of DeviceCORONARY DRUG-ELUTING STENT
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key11807782
MDR Text Key250223894
Report Number2134265-2021-05938
Device Sequence Number1
Product Code NIQ
Combination Product (y/n)Y
Reporter Country CodeCH
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation
Type of Report Initial
Report Date 05/11/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/11/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Expiration Date01/02/2022
Device Model Number10622
Device Catalogue Number10622
Device Lot Number0025022004
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received04/26/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured01/03/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 05/11/2021 Patient Sequence Number: 1
-
-