Catalog Number 0684-00-0604
Device Problems Restricted Flow rate (1248); Inappropriate Waveform (2536); Optical Problem (3001); Pressure Problem (3012)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 05/21/2021
Event Type  malfunction  
Manufacturer Narrative
Event site postal code: (b)(6). The device has not been returned to the manufacturer so we are unable to complete an evaluation. If provided we will send a supplemental report with our additional findings. Complaint record id # (b)(4).
 
Event Description
It was reported that after approximately one day of intra-aortic balloon (iab) therapy, the console indicated that iab catheter inspection was required. It was also reported that the console indicated that an optical sensor failure had occurred and the blood pressure values were no longer displayed. The console continued to pump, but the blood pressure waveform was almost self-pulse and there was no augmentation pressure waveform displayed. Since the patient's hemodynamics were stable, the iab was removed. There was no patient harm or adverse event reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameTRANS-RAY PLUS 7.5 FR. 35CC IAB
Type of DeviceSYSTEM, BALLOON, INTRA-AORTIC AND CONTROL
Manufacturer (Section D)
DATASCOPE CORP. - FAIRFIELD
15 law drive
fairfield NJ
Manufacturer (Section G)
DATASCOPE CORP. - FAIRFIELD
15 law drive
fairfield NJ
Manufacturer Contact
dorota wolpiuk
15 law drive
fairfield, NJ 
MDR Report Key11978939
MDR Text Key255734990
Report Number2248146-2021-00376
Device Sequence Number1
Product Code DSP
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation
Type of Report Initial,Followup
Report Date 08/11/2021
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received06/10/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Catalogue Number0684-00-0604
Device Lot Number3000115653
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received08/11/2021
Was Device Evaluated by Manufacturer? No
Date Device Manufactured02/26/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device?
Type of Device Usage Initial

-
-