Model Number 190610
Device Problems Mechanical Problem (1384); Reflux within Device (1522)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/14/2021
Event Type  malfunction  
Manufacturer Narrative
The plant investigation is in process. A supplemental mdr will be submitted upon completion of this activity.
 
Event Description
A user facility biomedical technician (bmt) reported that a 2008k2 hemodialysis (hd) machine experienced a saline bag backfill during the setup (prime) process in dialysis mode. The bmt stated there is an air separator adapter board installed on this machine. The bmt verified there was no patient involvement associated with the reported issues. Upon further inspection of the machine, the bmt discovered that one of the ball bearings in the arterial hansen connector was missing. This was generating blockage on the arterial side of the dialysate, and effectively pushing the saline back into the bag. The machine was in the setup process in dialysis mode when this occurred. User error was not a contributing factor. The machine had over 50,000 hours on it at the time of the event. The machine did not give any filling programs. The bmt confirmed the machine had upgrades for the changes being effected (cbe) completed, and verified that the drain line length and height were within specification. A quick disconnect is reportedly used on the drain line. To resolve the reported issue, the bmt replaced the air separator chamber and the arterial hansen connector. The machine was subsequently returned to service. The used parts were not available to be returned for evaluation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name2008K2 HEMODIALYSIS SYS. OLC/DIASAFE PLS
Type of DeviceDIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM
Manufacturer (Section D)
CONCORD MANUFACTURING
director, quality systems
4040 nelson avenue
concord CA 94520
Manufacturer (Section G)
CONCORD MANUFACTURING
director, quality systems
4040 nelson avenue
concord CA 94520
Manufacturer Contact
matthew amaral
920 winter st
waltham, MA 02451
7816999758
MDR Report Key12013289
MDR Text Key257471822
Report Number2937457-2021-01271
Device Sequence Number1
Product Code KDI
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K994267
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,health professional
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup,Followup
Report Date 07/08/2021
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received06/16/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Model Number190610
Device Catalogue Number190610
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Device AgeMO
Event Location No Information
Date Manufacturer Received07/07/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured01/07/2010
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse

-
-