Catalog Number 823832
Device Problem Infusion or Flow Problem (2964)
Patient Problem Failure of Implant (1924)
Event Date 06/16/2021
Event Type  Injury  
Manufacturer Narrative
An investigation has been initiated based on the reported information.Upon completion of the investigation, a follow-up report will be submitted.
 
Event Description
1 of 3 reports.Other mfg report numbers: 3013886523-2021-00287.3013886523-2021-00288.A facility reported a codman hakim programmable valve and catheters (823073 and 823074) were implanted into a (b)(6) patient on (b)(6) 2021 with removal of the device occurring 30 minutes later.The physician found that there was no cerebral spinal fluid flowing out from the abdominal catheter.The physician disconnected the abdominal catheter with the valve and there was no cerebral spinal fluid flowing out from the valve.Due to the patients age, the physician retrieved the hakim valve and catheters and changed with the device of another company to complete the procedure and limit the anesthesia time.A 30-minute surgical delay was reported due to the shunt adverse event.The patient is stable.
 
Manufacturer Narrative
The valve was returned for evaluation.Device history record (dhr): the product code 823832 with lot 4302823 conformed to the specifications when released to stock.Failure analysis: the valve was visually inspected; no defects were noted.The position of the cam when valve was received was 100mmh2o.The valve was hydrated.The catheters were irrigated no occlusions were noted.The valve was leak tested and no leaks noted.The valve passed the test for programming, occlusion, reflux, siphon guard and pressure.No root cause could be determined as the technician could not confirm any problem with the valve at the time of investigation.The possible root cause for the issue reported by the customer, could be due to biological debris and protein build up interfering with the valve mechanism, at the time of investigation no functional issues were noted.
 
Event Description
N/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PROG VALVE INLINE W SG
Type of Device
CHPV WITH SG
Manufacturer (Section D)
INTEGRA LIFESCIENCES SWITZERLAND SAR
rue girardet 29
rue girardet 29
le locle
SZ 
MDR Report Key12116215
MDR Text Key260240953
Report Number3013886523-2021-00286
Device Sequence Number1
Product Code JXG
Combination Product (y/n)N
PMA/PMN Number
K053107
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign
Type of Report Initial,Followup
Report Date 08/06/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/05/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue Number823832
Device Lot Number4302823
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/16/2021
Date Manufacturer Received07/21/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-