TANDEM DIABETES CARE T:SLIM X2 INSULIN PUMP WITH BASAL-IQ TECHNOLOGY AUTOMATED INSULIN DOSING, THRESHOLD SUSPEND Back to Search Results
Model Number 1000096
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Fall (1848); Bone Fracture(s) (1870); Hypoglycemia (1912)
Event Date 06/17/2021
Event Type  Injury  
Manufacturer Narrative
No product was returned for evaluation. Should new relevant information become available, a supplemental report will be submitted. (b)(4).
 
Event Description
It was reported that the customer experienced a blood glucose (bg) level of 49 mg/dl, resulting in customer falling and fracturing wrist and stubbed toes. The cause was unknown; however, customer's continuous glucose monitor was not available due to a non-tandem sensor issue, and customer was unaware of bg level. The customer went to the emergency room and was subsequently hospitalized. Bg was treated with glucose tablets and consumption of carbohydrates. Reportedly, the customer was released on 6/18/2021 with the issue resolved; however customer required surgery for fractured wrist. System check with tandem technical support confirmed that the pump was functioning as intended.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameT:SLIM X2 INSULIN PUMP WITH BASAL-IQ TECHNOLOGY
Type of DeviceAUTOMATED INSULIN DOSING, THRESHOLD SUSPEND
Manufacturer (Section D)
TANDEM DIABETES CARE
11075 roselle street
san diego CA 92121
Manufacturer Contact
mick trier
san diego, CA 92121
8584011451
MDR Report Key12183291
MDR Text Key262022455
Report Number3013756811-2021-75244
Device Sequence Number1
Product Code OZO
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K201214
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer
Reporter Occupation
Type of Report Initial
Report Date 07/16/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/16/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Model Number1000096
Device Catalogue Number1000898
Was Device Available for Evaluation? No
Is the Reporter a Health Professional?
Was the Report Sent to FDA? Yes
Event Location No Information
Date Manufacturer Received06/25/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/01/2019
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse

Patient Treatment Data
Date Received: 07/16/2021 Patient Sequence Number: 1
-
-