• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON, S.A. BD PLASTIPAK CONCENTRIC LUER LOCK SYRINGE; PISTON SYRINGE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON, S.A. BD PLASTIPAK CONCENTRIC LUER LOCK SYRINGE; PISTON SYRINGE Back to Search Results
Catalog Number 300865
Device Problem Fluid/Blood Leak (1250)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/07/2021
Event Type  malfunction  
Manufacturer Narrative
Unknown.The date received by manufacturer has been used for this field.A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported that the bd plastipak¿ concentric luer lock syringe leaked from the back piston.The following information was provided by the initial reporter: "setting up a propofol aivoc mode anaesthesia, leakage of the syringe at the back on the piston side syringe change".
 
Manufacturer Narrative
The following fields were updated due to additional information: d.10.Device available for evaluation?: yes.D.10.Returned to manufacturer on: 7/21/2021.H.6.Investigation: one used sample was received for evaluation by our quality engineer.Through visual inspection of the sample, a leakage between the stopper ribs was observed.The product was disassembled for further inspection, there was no damage noted in the plunger rod that could have caused a leak and the stopper was verified to be properly assembled, however, it was noted there was damage on the barrel which can prevent a proper seal when the stopper moves across this point, resulting in the leak observed.A device history review was performed for the reported lot 2012082, no deviations or non-conformances were identified during the manufacturing process that could have contributed to this issue.Final products in this manufacturing line, for this reference are sampled and they are subjected to visual and functional inspections during the different manufacturing sub-processes according to procedures, including leakage testing.The returned sample underwent these tests and product was verified to meet required specifications.Root cause could not be determined.
 
Event Description
It was reported that the bd plastipak¿ concentric luer lock syringe leaked from the back piston.The following information was provided by the initial reporter: "setting up a propofol aivoc mode anaesthesia leakage of the syringe at the back on the piston side syringe change".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD PLASTIPAK CONCENTRIC LUER LOCK SYRINGE
Type of Device
PISTON SYRINGE
Manufacturer (Section D)
BECTON DICKINSON, S.A.
camino de valdeolivia
s/n
san agustin de guadalix
MDR Report Key12281862
MDR Text Key265201602
Report Number3003152976-2021-00452
Device Sequence Number1
Product Code FMF
Combination Product (y/n)N
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Type of Report Initial,Followup
Report Date 08/11/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/05/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number300865
Device Lot Number2012082
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/21/2021
Date Manufacturer Received08/11/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-