Model Number 2570-02-100
Device Problems Break (1069); Device-Device Incompatibility (2919)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/01/2021
Event Type  malfunction  
Manufacturer Narrative
Product complaint # (b)(4). If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
It was reported that when the surgeon used the reamer with a handpiece and chuck, the reamer stuck into the bone and only the handpiece rotated. In that time, the connection part between the reamer and chuck broke and the surgeon couldn¿t disconnect them. The surgeon removed the remained reamer in the cavity with pliers and the surgery was completed successfully. There was a surgical delay of five minutes.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameSUMMIT SZ2/3 TAPERED REAMER
Type of DeviceHIP INSTRUMENTS : REAMERS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
Manufacturer (Section G)
DEPUY ORTHOPAEDICS, INC. 1818910
700 orthopaedic dr.
warsaw IN 46581 0988
Manufacturer Contact
kara ditty-bovard
700 orthopaedic dr.
warsaw, IN 46581-0988
6107428552
MDR Report Key12312020
MDR Text Key266164209
Report Number1818910-2021-17679
Device Sequence Number1
Product Code HTO
UDI-Device Identifier10603295143000
UDI-Public10603295143000
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 08/02/2021
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received08/12/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Model Number2570-02-100
Device Catalogue Number257002100
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received09/29/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unkown

-
-