Model Number W1TR04
Device Problem Electromagnetic Interference (1194)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/02/2021
Event Type  malfunction  
Manufacturer Narrative
Concomitant medical products: 429678 lead implanted: (b)(6) 2016. If information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported that there was a lead impedance warning on the right ventricular (rv) lead for high impedance. There was also a polarity switch to unipolar pace/sense. The rv lead was reprogrammed back to bipolar and remains in use. The interrogation also noted episodes of electromagnetic interference. The cardiac resynchronization therapy pacemaker (crt-p) remains in use. No patient complications have been reported as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NamePERCEPTA CRT-P MRI SURESCAN
Type of DevicePULSE GENERATOR, PACEMAKER, IMPLANTABLE, WITH CARDIAC RESYNCHRONIZATION (CRT-P)
Manufacturer (Section D)
MEDTRONIC EUROPE SARL
route du molliau 31
case postale
tolochenaz vaud 1131
SZ 1131
Manufacturer (Section G)
MEDTRONIC EUROPE SARL
route du molliau 31
case postale
tolochenaz vaud 1131
SZ 1131
Manufacturer Contact
paula bixby
8200 coral sea st ne
mounds view, MN 55112
7635055378
MDR Report Key12337831
MDR Text Key267109118
Report Number9614453-2021-03269
Device Sequence Number1
Product Code NKE
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P010015
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation
Type of Report Initial
Report Date 08/18/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/18/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date11/14/2021
Device Model NumberW1TR04
Device Catalogue NumberW1TR04
Was Device Available for Evaluation? No
Is the Reporter a Health Professional?
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received08/02/2021
Was Device Evaluated by Manufacturer? No Answer Provided
Date Device Manufactured05/15/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 08/18/2021 Patient Sequence Number: 1
Treatment
5076-52 LEAD, 5076-45 LEAD
-
-