Model Number SAM500P
Device Problems Failure to Sense (1559); Defibrillation/Stimulation Problem (1573); Inadequacy of Device Shape and/or Size (1583); Device Sensing Problem (2917); Audible Prompt/Feedback Problem (4020)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/16/2021
Event Type  malfunction  
Manufacturer Narrative
Heartsine has requested return of the device for investigation.Upon completion, the conclusions will be submitted in a follow-up report.
 
Event Description
As patient impedance increases, the sensing of a child patient when an adult pad-pak is inserted will likely result in a reduced shock energy being delivered to the patient which may result in adverse consequences.No patient involvement.
 
Manufacturer Narrative
Heartsine's investigation confirmed the reported fault as the device was found to be giving incorrect child patient prompts with an adult pad-pak installed.The investigation determined a failure of the reed switch which controls whether the device recognises an adult or child patient pad-pak insertion.If an child patient is detected but an adult is connected, the higher the impedance the lower the shock energy.There is potential to cause an adverse event but it is dependent on both the impedance of the patient and the switch failing.
 
Event Description
The distributor contacted heartsine to report that their device was prompting a child patient when an adult pad-pak was inserted.As patient impedance increases, the sensing of a child patient when an adult pad-pak is inserted will likely result in a reduced shock energy being delivered to the patient which may result in adverse consequences.There was no patient involvement reported with the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PACKAGE,500P,PP03,INTL EN,500-BAS-UK-10
Type of Device
AUTOMATED EXTERNAL DEFIBRILLATOR
Manufacturer (Section D)
HEARTSINE TECHNOLOGIES LTD
207 airport road west
belfast BT3 9 ED
EI  BT3 9ED
MDR Report Key12346852
MDR Text Key268768162
Report Number3004123209-2021-00222
Device Sequence Number1
Product Code MKJ
Combination Product (y/n)N
PMA/PMN Number
P160008
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor
Type of Report Initial,Followup
Report Date 10/11/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/20/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Model NumberSAM500P
Device Catalogue Number500-BAS-UK-10
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/22/2021
Date Manufacturer Received10/08/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-