MAUDE Adverse Event Report: ANGIODYNAMICS XCELA POWER INJECTABLE PICC; PERIPHERALLY INSERTED CENTRAL CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ANGIODYNAMICS XCELA POWER INJECTABLE PICC; PERIPHERALLY INSERTED CENTRAL CATHETER Back to Search Results
Catalog Number 60M701532
Device Problem Material Discolored (1170)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/29/2021
Event Type  malfunction  
Manufacturer Narrative
The reported device is not available for return to the manufacturer for a device evaluation.An investigation into the root cause for product problem is currently in progress.The results of the investigation will be sent via a follow up medwatch.Reference (b)(4).
 
Event Description
1st event reported via (b)(4), 1317056-2021-00144.5th of 8 reported events: a territory manager reported an end user had an issue with a can 5f dual xcela picc - (b)(6) kit.It was reported that there was a discoloration of the picc lumen.On visual inspection, one lumen of the picc noted to be cloudy or discolored white/grey.The lumen was known to have had undiluted etoposide infused within.The picc was removed from the patient and replaced with a new of the same device.The patient did not experience any adverse effects, harm, or require medical intervention because of this incident.It was indicated the reported device is not available for return to the manufacturer for a device evaluation.
 
Manufacturer Narrative
In lieu of a reported lot number, a ship history report (shr) was generated for item number (h96560m7015321) in order to ascertain the last three lots shipped to the reporting customer in the six (6) months prior to the procedure date.A review of the device history records was performed for the indicated lots for any deviations related to the reported failure mode of the complaint.The review confirms that the lots met all material, assembly and performance specifications; i.E.No ncr associated with reported failure mode.Reference (b)(4).Correction to section h10: ammended upn number from h96560m7015311 to h96560m7015321.
 
Manufacturer Narrative
As the reported device was not returned, angiodynamics is unable to perform a device evaluation.Pictures were provided showing extension tubing is cloudy in appearance.The customer's reported complaint description is confirmed based on pictures provided; however, as no complaint sample was returned for evaluation, a definitive root cause for the event cannot be determined.A potential root cause for the discoloration may be the result of the chemical/medicine that the customer was injecting through the catheter.In lieu of a reported lot number, a ship history report (shr) was generated for item number (h96560m7015311) in order to ascertain the last three lots shipped to the reporting customer in the six (6) months prior to the procedure date.A review of the device history records was performed for the indicated lots for any deviations related to the reported failure mode of the complaint.The review confirms that the lots met all material, assembly and performance specifications; i.E.No ncr associated with reported failure mode.A review of the angiodynamics complaint system noted no adverse trends for this complaint type and product family.This type of complaint will continue to be monitored for trends.Reference (b)(4).
 
Manufacturer Narrative
As the reported device was not returned, angiodynamics is unable to perform a device evaluation.The customer's reported complaint description is confirmed based on the pictures provided.Complaint samples for same issue from same customer were returned per (b)(4) (reference reports: 1317056-2021-00144, 1317056-2021-00152, 1317056-2021-00153, and 1317056-2021-00165, respectively).The customer's reported complaint description of cloudy extension tubing is confirmed based on evaluation of returned picc complaint samples.The extension tubing was sectioned, and it was observed that a sticky film was present on the inside surface that could be wiped off with isopropyl alcohol, leaving the extension tubing clear with no evidence of degradation.The composition of this film is unknown, however, based upon the absence of any damage to the extension tubing underneath the film, it appears to be a residue or precipitate from the infused drugs.Based on the sample analysis, these devices did not malfunction.It is possible that the film observed on the id of the extension tubes was the result of instability of the etoposide mixture used/infused causing the drug to precipitate from solution as the observed film.The most likely root cause for the discoloration is drug precipitate.This is an issue of customer use of the picc for a specific patient population drug therapy and not a picc device malfunction.A review of the device history records was performed for the indicated lots for any deviations related to the reported failure mode of the complaint.The review confirms that the lots met all material, assembly and performance specifications; i.E.No ncr associated with reported failure mode.A review of the angiodynamics complaint system noted no adverse trends for this complaint type and product family.This type of complaint will continue to be monitored for trends.Reference: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XCELA POWER INJECTABLE PICC
Type of Device
PERIPHERALLY INSERTED CENTRAL CATHETER
Manufacturer (Section D)
ANGIODYNAMICS
10 glens falls technical park
glens falls, ny 12801 NY 12801
MDR Report Key12362622
MDR Text Key268060909
Report Number1317056-2021-00155
Device Sequence Number1
Product Code LJS
UDI-Device IdentifierH96560M7015321
UDI-PublicH96560M7015321
Combination Product (y/n)N
PMA/PMN Number
K070002
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup,Followup,Followup
Report Date 10/29/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/24/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number60M701532
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Date Manufacturer Received10/28/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-