Catalog Number 302633
Device Problem Material Separation (1562)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/30/2021
Event Type  malfunction  
Manufacturer Narrative
Date of event: unknown. The date received by manufacturer has been used for this field. A device evaluation is anticipated but has not yet begun. Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported that the needle pulled out of the bd solomed¿ syringe hub and leaked hemax erythron medication. The following information was provided by the initial reporter, translated from (b)(6) to english: "patient son went to apply the medicine to his father, the needle remained in the father and the rest remained in his hand, dismembering (disconnected) the needle from the plunger. When he went to remove the needle from his father's arm. Lost his balance and broke the mask he was using at the time to apply the medicine. The liquid gushed everywhere and then he had to redo the injection, using more medicine. Medicine: hemax erythron. ".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameBD SOLOMED SYRINGE
Type of DevicePISTON SYRINGE
Manufacturer (Section D)
BECTON DICKINSON IND. CIRURGICAS LTDA
550 rua cyro correia pereira
curitiba
Manufacturer (Section G)
BECTON DICKINSON IND. CIRURGICAS LTDA
550 rua cyro correia pereira
curitiba
Manufacturer Contact
katie swenson
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key12380504
MDR Text Key272029915
Report Number3003916417-2021-00216
Device Sequence Number1
Product Code FMF
Combination Product (y/n)N
Reporter Country CodeBR
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,foreign,other
Reporter Occupation
Type of Report Initial,Followup
Report Date 09/16/2021
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received08/27/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Catalogue Number302633
Device Lot Number0225665
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/10/2021
Is the Reporter a Health Professional?
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received09/16/2021
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured08/12/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-