• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BD INSYTE¿ AUTOGUARD¿ SHIELDED IV CATHETER; INTRAVASCULAR CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD INSYTE¿ AUTOGUARD¿ SHIELDED IV CATHETER; INTRAVASCULAR CATHETER Back to Search Results
Model Number 381534
Device Problem Retraction Problem (1536)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/11/2021
Event Type  malfunction  
Manufacturer Narrative
Date of event: unknown.The date received by manufacturer has been used for this field.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported that the bd insyte¿ autoguard¿ shielded iv catheter experienced a needle that would not retract.The following information was provided by the initial reporter: my preop nurse manager states the needle is not retracting into the safety hubs on the catheter iv insyte products, and this happening frequently with her staff.
 
Event Description
It was reported that the bd insyte¿ autoguard¿ shielded iv catheter experienced a needle that would not retract.The following information was provided by the initial reporter: my preop nurse manager states the needle is not retracting into the safety hubs on the catheter iv insyte products, and this happening frequently with her staff.
 
Manufacturer Narrative
H.6.Investigation: since no samples displaying the condition reported were available for examination, we were unable to fully investigate this incident.A device history record review showed no non-conformances associated with this issue during the production of this batch.The complaint could not be confirmed and the root cause is undetermined.H3 other text : see h.10.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD INSYTE¿ AUTOGUARD¿ SHIELDED IV CATHETER
Type of Device
INTRAVASCULAR CATHETER
MDR Report Key12444312
MDR Text Key270621281
Report Number1710034-2021-00792
Device Sequence Number1
Product Code FOZ
UDI-Device Identifier30382903815341
UDI-Public30382903815341
Combination Product (y/n)N
PMA/PMN Number
K201075
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other,user facility
Type of Report Initial,Followup
Report Date 09/23/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/09/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date02/29/2024
Device Model Number381534
Device Catalogue Number381534
Device Lot Number1084467
Was Device Available for Evaluation? No
Date Manufacturer Received09/23/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured03/25/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-