SYNTHES GMBH TFNA FENESTRATED HELICAL BLADE 85MM - STERILE ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES Back to Search Results
Catalog Number 04.038.385S
Device Problem Device-Device Incompatibility (2919)
Patient Problem Hemorrhage/Bleeding (1888)
Event Date 08/11/2021
Event Type  Injury  
Manufacturer Narrative
Additional product code: ktt complainant part is not expected to be returned for manufacturer review/investigation. Without a lot number the device history records review could not be completed. Product was not returned. Based on the information available, it has been determined that no corrective and/or preventative action is proposed. This complaint will be accounted for and monitored via post market surveillance activities. If additional information is made available, the investigation will be updated as applicable. Device was used for treatment, not diagnosis. If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Device report from synthes (b)(6) reports an event as follows: it was reported that on (b)(6) 2021, the patient underwent the open reduction internal fixation surgery for proximal fracture of shaft of femur. The surgeon inserted the blade according to the surgical technique, but when the surgeon confirmed via imaging, the blade was not inserted properly. The blade was removed once, re-inserted, and the surgery was completed successfully with a less than thirty (30) minute delay. In addition, because the amount of bleeding was larger than planned, the doctor did not use a screw for distal transverse arrest. The patient was reported stable after the procedure. This report is for a helical blade. This is report 1 of 1 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameTFNA FENESTRATED HELICAL BLADE 85MM - STERILE
Type of DeviceROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
SYNTHES GMBH
eimattstrasse 3
oberdorf 4436
SZ 4436
Manufacturer (Section G)
SYNTHES SELZACH
bohackerweg 5
selzach 2545
SZ 2545
Manufacturer Contact
kara ditty-bovard
1302 wright lane east
west chester, PA 19380
6107195000
MDR Report Key12527477
MDR Text Key275404810
Report Number8030965-2021-08022
Device Sequence Number1
Product Code HSB
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K160167
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 08/27/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/24/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator
Device Catalogue Number04.038.385S
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received08/27/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device?
Type of Device Usage Unkown

Patient Treatment Data
Date Received: 09/24/2021 Patient Sequence Number: 1
-
-