Model Number 1012278-08
Device Problems Material Rupture (1546); Difficult to Advance (2920)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/02/2021
Event Type  malfunction  
Manufacturer Narrative
The device was not returned for evaluation. A review of the lot history record and complaint history could not be conducted because the lot number was not provided. The investigation was unable to determine a conclusive cause for the reported complaint. There is no indication of a product quality issue with respects to the design, manufacture, or labeling of the device.
 
Event Description
It was reported that during a right coronary artery (rca) intervention a non-abbott device fractured in the vessel and the catheter tip could not be snared. A trek 4. 0x8mm balloon dilatation catheter was advanced, but had some difficulty passing the retained catheter tip in the rca. Once at the desired location, the balloon was inflated to 16 atmospheres and then to 14 atmospheres for 12 seconds in the mid rca at the site of the broken catheter tip before the balloon burst. The device was removed without issue. There was no reported adverse patient effect and no clinically significant delay in the procedure. Another balloon was used to continue the procedure. No additional information regarding this issue was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameTREK CORONARY DILATATION CATHETER
Type of DeviceCORONARY DILATATION CATHETER
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR COSTA RICA, REG # 3009564766
52 calle 3 b31 coyol free zone
el coyol alajuela
CS
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key12550615
MDR Text Key274008065
Report Number2024168-2021-08754
Device Sequence Number1
Product Code LOX
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K103110
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation
Type of Report Initial
Report Date 09/29/2021
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received09/29/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Model Number1012278-08
Device Catalogue Number1012278-08
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received09/17/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-