Model Number PVPM
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Diarrhea (1811); Inflammation (1932); Nausea (1970); Pain (1994); Chills (2191); Hernia (2240); Weight Changes (2607); Decreased Appetite (4569)
Event Type  Injury  
Manufacturer Narrative
To date, the device has not been returned. If the product is returned for evaluation, any further information derived from the evaluation will be submitted in a supplemental 3500a form.
 
Event Description
It was reported by an attorney that the patient underwent hernia repair surgery on (b)(6) 2015 and mesh was implanted. It was reported that the patient underwent removal surgery on (b)(6) 2019 during which the surgeon noted a peritoneal flap was created lateral to the left rectus muscle. It appeared to be very thin and palpable, so a subfascial plane was created to the midline, where a large mass effect of a contracted mesh was identified with recurrent hernia noted. It was reported that the patient experienced severe pain, nausea, diarrhea, chills, inflammation, loss of appetite and extreme weight loss. No additional information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NamePVP MEDIUM 6.4CM X 6.4CM
Type of DeviceMESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON INC.-GMBH
p.o. box 1409
norderstedt D2284 1
GM D22841
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
MDR Report Key12566787
MDR Text Key274435884
Report Number2210968-2021-09122
Device Sequence Number1
Product Code FTL
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K061533
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other
Reporter Occupation
Type of Report Initial,Followup,Followup,Followup
Report Date 09/29/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/04/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Expiration Date05/31/2017
Device Model NumberPVPM
Device Catalogue NumberPVPM
Device Lot NumberJG8DKCA0
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received03/01/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/17/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 10/04/2021 Patient Sequence Number: 1
-
-