Model Number 7005
Device Problem Material Deformation (2976)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/10/2021
Event Type  malfunction  
Manufacturer Narrative
Initial reporter facility name: (b)(6).Returned product consisted of a quantum maverick balloon catheter in two sections.The shaft, hypotube, tip, and balloon were microscopically and visually examined.The balloon was tightly folded.There were numerous kinks throughout the hypotube with a complete hypotube separation 49cm distal of the strain relief.The hypotube fracture surfaces were ovaled, which suggests the device was kinked prior to separation.
 
Event Description
Reportable based on device analysis completed on (b)(6) 2021.It was reported that shaft kink occurred.The target lesion was located at the left main coronary artery.A 4.0mm x 8mm quantum maverick balloon catheter was advanced for dilatation.However, it was noted that the shaft was kinked.The procedure was completed with another of the same device.No patient complications were reported and the patient status was stable.However, returned device analysis revealed hypotube detached/separated.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUANTUM MAVERICK
Type of Device
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC SCIMED, INC
two scimed place
maple grove MN 55311
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key12579281
MDR Text Key274825335
Report Number2134265-2021-12193
Device Sequence Number1
Product Code LOX
UDI-Device Identifier08714729392606
UDI-Public08714729392606
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
P860019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation Physician
Type of Report Initial
Report Date 10/05/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/05/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/20/2023
Device Model Number7005
Device Catalogue Number7005
Device Lot Number0025381986
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/07/2021
Is the Reporter a Health Professional? Yes
Date Manufacturer Received09/20/2021
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/20/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age76 YR
Patient Weight58
-
-