Catalog Number 199725740S
Device Problem Device Slipped (1584)
Patient Problem Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Type  Injury  
Manufacturer Narrative
Complainant part is not expected to be returned for manufacturer review/ investigation.(b)(4).Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Device report from synthes reports an event in (b)(6) as follows: it was reported that the primary tlif (l5/s1) procedure was performed on (b)(6) 2021 to treat the 5th lumbar spondylolisthesis.The procedure was completed without surgical delay.On an unknown date it was found that the cage had backed out toward the spinal canal.Two screws deployed on both sides of s1 had been quite loose/ wobbly.Also, screw insertions were off the targeted lesion (the screws were supposed to be deployed at the promontorium ossis sacri area).The bone surface (where the loose screws were deployed) had a crack reaching inward.On (b)(6) 2021, the patient underwent the revision procedure.No further information is available.This report is for one (1) 5.5 exp verse can scr 7.0 x 40.This is report 2 of 2 for complaint (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
5.5 EXP VERSE CAN SCR 7.0X40
Type of Device
ORTHOSIS, SPINAL PEDICLE FIXATION, FOR DDD
Manufacturer (Section D)
MEDOS INTERNATIONAL SàRL CH
chemin-blanc 38
le locle 02400
SZ  02400
Manufacturer (Section G)
SENTIO (INNOVATIVE SURGICAL SOLUTIONS, LLC)
50461 west pontiac trail
wixom MI 48393
Manufacturer Contact
kara ditty-bovard
325 paramount drive
raynham, MA 02767
6103142063
MDR Report Key12634761
MDR Text Key277152950
Report Number1526439-2021-02179
Device Sequence Number1
Product Code NKB
UDI-Device Identifier10705034440927
UDI-Public(01)10705034440927
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
K142185
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial
Report Date 09/16/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/14/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number199725740S
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received09/16/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-