MAUDE Adverse Event Report: STRYKER TRAUMA KIEL TROCHANTERIC NAIL KIT, TI GAMMA3® Ø11X180MM X 120° ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER TRAUMA KIEL TROCHANTERIC NAIL KIT, TI GAMMA3® Ø11X180MM X 120° ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES Back to Search Results
Model Number 3120-1180S
Device Problem Mechanical Jam (2983)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/22/2021
Event Type  malfunction  
Manufacturer Narrative
The device will not be returned. If additional information becomes available, it will be provided in a supplemental report.
 
Event Description
Customer reported the following issue regarding a gamma nail ref. 3120-1180s, lot k05cc65 and the ancillary material necessary for its installation (nail, target device, bolt): "during an operation on (b)(6) 2021, the material was fitted without any problems until the nail had to be removed from the target device to complete the operation: it was impossible to unscrew. The consequences were a doubling of the operation time due to the need to remove everything to start the whole operation again, and the need to use another ancillary and another nail less adapted to the patient".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameTROCHANTERIC NAIL KIT, TI GAMMA3® Ø11X180MM X 120°
Type of DeviceROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
STRYKER TRAUMA KIEL
prof. kuentscher-strasse 1-5
schoenkirchen/kiel D-242 32
GM D-24232
Manufacturer (Section G)
STRYKER TRAUMA KIEL
prof. kuentscher-strasse 1-5
schoenkirchen/kiel D-242 32
GM D-24232
Manufacturer Contact
sharon rivas
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key12849558
MDR Text Key282918947
Report Number0009610622-2021-00795
Device Sequence Number1
Product Code HSB
Combination Product (y/n)N
Reporter Country CodeFR
PMA/PMN Number
K034002
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Pharmacist
Type of Report Initial,Followup
Report Date 03/07/2022
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received11/19/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Model Number3120-1180S
Device Catalogue Number31201180S
Device Lot NumberK05CC65
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/09/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/30/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-