Catalog Number 466P306AU
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Internal Organ Perforation (1987); Perforation of Vessels (2135)
Event Date 12/26/2018
Event Type  Injury  
Event Description
As reported by the legal brief, the patient underwent placement of a trapease vena cava filter. The report states that the filter subsequently malfunctioned and caused injury and damage to the patient including, but not limited to some of the filter struts have penetrated 5 mm through the wall of the inferior vena cava (ivc) into the pericaval/mesenteric fat.
 
Manufacturer Narrative
Initial reporter: occupation: other, senior counsel, litigation. Please note that the exact event date is unknown and the event date in section date of event is the complaint awareness date. As reported, the patient underwent placement of a trapease vena cava filter. The indication for the filter placement was not reported. At some point after the filter implantation, the patient became aware that filter struts had penetrated through the wall of the inferior vena cava (ivc) by up to 5mm and into the pericaval and/or mesenteric fat. The product was not returned for analysis and the sterile lot number has not been provided; therefore, no device analysis nor device history record review could be performed. The trapease vena cava filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the ivc for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pe where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pe where anticoagulant therapy has failed, or is contraindicated. The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart. Without images or procedural films for review, the reported ivc perforation could not be confirmed and the exact cause could not be determined. A review of the instructions for use (ifu) notes vessel damage such as intimal tears and perforation as procedural complications related to ivc filters. Studies have noted a greater than 80% perforation rate overall, with all filters imaged after 71 days from implantation revealing some level of perforation. Clinical factors that may have influenced the event include the patient¿s pre-existing co-morbidities, pharmacological issues and lesion characteristics. Given the limited information available for review, there is nothing to suggest that a malfunction in the design and manufacturing process of the device; therefore, no corrective action will be taken. Should additional information become available, the file will be updated accordingly. Please note that this is the initial report for this product.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameTRAPEASE PVCF FEM/JUG 55CM CSI
Type of DeviceFILTER, INTRAVASCULAR, CARDIOVASCULAR
Manufacturer (Section D)
CORDIS CORPORATION
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer (Section G)
CORDIS CORPORATION
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer Contact
karla castro
14201 nw 60 avenue
miami lakes, FL 33014
7863138372
MDR Report Key12975474
MDR Text Key284830441
Report Number9616099-2021-05167
Device Sequence Number1
Product Code DTK
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K020316
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Company Representative
Reporter Occupation
Type of Report Initial,Followup,Followup
Report Date 02/03/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/10/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Catalogue Number466P306AU
Device Lot NumberR0608222
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received01/17/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/17/2008
Is the Device Single Use? Yes
Type of Device Usage Initial

Patient Treatment Data
Date Received: 12/10/2021 Patient Sequence Number: 1
Treatment
UNK 6F SHEATH, UNK GUIDEWIRE
-
-