MEDTRONIC NEUROMODULATION IMPLANTABLE NEUROSTIMULATOR; STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINS
|
Back to Search Results |
|
Model Number NEU_INS_STIMULATOR |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
Irritability (2421)
|
Event Date 10/20/2021 |
Event Type
Injury
|
Manufacturer Narrative
|
This value is the average age of the patients reported in the article as specific patients could not be identified.This value reflects the gender of the majority of the patients reported in the article as specific patients could not be identified.Date of event: please note that this date is based off of the date of publication of the article as the event dates were not provided in the published literature.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
M.S.Oudijn, r.J.T.Mocking, r.R.Wijnker, a.Lok, p.R.Schuurman, p.Van den munckhof, a.A.Van elburg, d.Denys.Deep brain stimulation of the ventral anterior limb of the capsula interna in patients with treatment-refractory anorexia nervosa.Doi: 10.1016/j.Brs.2021.10.387.Anorexia nervosa (an) is a severe and often chronic psychiatric disorder with high morbidity and mortality [1].Pilot studies and cases showed mixed but promising effects of deep brain stimulation (dbs) as a last-resort treatment option for life-threatening treatment-refractory an.Reported events: it was reported that there were 9 events of self-destructive behavior (autointoxication, auto-mutilation and aggression) that were possibly related to the dbs device/therapy.It was reported that there were 2 events of hypomanic symptoms that were probably related to the dbs device/therapy. it was not possible to ascertain specific device information from the article or to match the reported event with any previously reported event.The devices were implanted for anorexia nervosa.
|
|
Manufacturer Narrative
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
M.S.Oudijn, r.J.T.Mocking, r.R.Wijnker, a.Lok, p.R.Schuurman, p.Van den munckhof, a.A.Van elburg, d.Denys.Deep brain stimulation of the ventral anterior limb of the capsula interna in patients with treatment-refractory anorexia nervosa.Doi: 10.1016/j.Brs.2021.10.387.Anorexia nervosa (an) is a severe and often chronic psychiatric disorder with high morbidity and mortality [1].Pilot studies and cases showed mixed but promising effects of deep brain stimulation (dbs) as a last-resort treatment option for life-threatening treatment-refractory an.Reported events: it was reported that there were 9 events of self-destructive behavior (autointoxication, auto-mutilation and aggression) that were possibly related to the dbs device/therapy.
|
|