• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY IRELAND UC VELYS ARRAY CLAMP; ORTHOPEDIC STEREOTAXIC INSTRUMENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY IRELAND UC VELYS ARRAY CLAMP; ORTHOPEDIC STEREOTAXIC INSTRUMENT Back to Search Results
Model Number 4515-70-107
Device Problem Device Slipped (1584)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/28/2021
Event Type  malfunction  
Manufacturer Narrative
Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.As of this date, the device has not been returned for evaluation; therefore, the reported condition cannot be confirmed and/or duplicated.Device manufacture date is unknown.The device serial or lot number is unknown.Concomitant medical devices and therapy dates, base station device and fixation pin device and array device, (b)(6) 2021.The device serial or lot number was unknown; therefore, udi: (b)(4).
 
Event Description
It was reported that during a surgical procedure, it was observed that the array clamp device while being used with an array device and a fixation pin, moved when the surgeon's forearm bumped the array.It was reported that the system was unable to recognize the array device at this point and so the decision was made to switch to manual.It was reported that there was no patient harm and the surgery was completed successfully.There was patient involvement.There were no injuries, medical intervention or prolonged hospitalization.All available information has been disclosed.If additional information should become available, a supplemental medwatch will be submitted accordingly.
 
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary: after multiple requests, the customer has not returned the device for evaluation / repair to any jnj site and therefore the complaint cannot be confirmed, and no conclusion can be drawn at this time.The complaint will be reopened upon receiving the device for repair from the customer.Device history lot: the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VELYS ARRAY CLAMP
Type of Device
ORTHOPEDIC STEREOTAXIC INSTRUMENT
Manufacturer (Section D)
DEPUY IRELAND UC
loughbeg ringaskiddy co.
cork
EI 
Manufacturer Contact
kara ditty-bovard
700 orthpaedic dr.
warsaw, IN 46581
6107428552
MDR Report Key13357699
MDR Text Key284450857
Report Number1818910-2022-01637
Device Sequence Number1
Product Code OLO
UDI-Device Identifier10603295519379
UDI-Public10603295519379
Combination Product (y/n)N
PMA/PMN Number
K202769
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/26/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/26/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number4515-70-107
Device Catalogue Number451570107
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received02/21/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-