Catalog Number UNK_SEL
Device Problems Device Appears to Trigger Rejection (1524); Naturally Worn (2988)
Patient Problems Unspecified Infection (1930); Loss of Range of Motion (2032); Metal Related Pathology (4530); Implant Pain (4561)
Event Date 01/28/2022
Event Type  Injury  
Event Description
As reported; "surgeon had a patient come in 2 weeks ago that had a reverse total shoulder reunion done at a different facility.The patient presented with shoulder stiffness and a lot of pain.X-rays showed aseptic loosening and surgeon suspected deep infection.During the surgery the surgeon noticed extreme metallosis on the glenoid side of the implant and he cleaned it all out by hand without instrumentation where the 2 peripheral screws stayed inside the glenoid and did not come out of the baseplate.Took all the implants out.After the case, upon close inspection of the glenoid baseplate he noticed that the peripheral screws where they lock into the baseplate through the threads had worn away due to aseptic loosening and infection.This had worn all the way through and the screws had pulled all the way through the baseplate.All implants were removed from the shoulder and a cement antibiotic spacer was put in.Surgeon reported that the patient is very happy with the outcomes.Implants were discarded by the hospital.No additional information is available.".
 
Manufacturer Narrative
The device will not be returned.If additional information becomes available, it will be provided in a supplemental report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN RSA REUNION PERIPHERAL SCREW
Type of Device
PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED
Manufacturer (Section D)
STRYKER GMBH
bohnackerweg 1
postfach
selzach 2545
SZ  2545
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer Contact
sharon rivas
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key13656568
MDR Text Key287344666
Report Number0008031020-2022-00082
Device Sequence Number1
Product Code KWS
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Physician
Type of Report Initial
Report Date 03/02/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/02/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Catalogue NumberUNK_SEL
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/04/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age58 YR
Patient SexMale
-
-