ARGON MEDICAL DEVICES L-CATH PICC S/L 26GA (1.9F) 0.60MM X 30CM Back to Search Results
Model Number 384539
Device Problems Crack (1135); Fluid/Blood Leak (1250)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/23/2022
Event Type  malfunction  
Event Description
Noticed fine cracks on the hub - leaking noted 12-18hrs after procedure.Picc had to be removed.
 
Manufacturer Narrative
Sample is unavailable for evaluation.Without such evident to review, the complaint cannot be confirmed.If additional information is provided in the future, a follow-up report will be submitted.
 
Manufacturer Narrative
A review of the dhr and inspection records could not be conducted since a lot number was not provided.According to the returned product experience report, there was no sample available for review.However, there was a video provided of the reported issue.Based on the video review, leakage was confirmed at the hub of the catheter.The customer stated "noticed fine cracks on the hub".Without the sample to review, it is not possible to conduct a thorough investigation of the alleged cracks in the hub.Several complaints for this part number have previously been received regarding a cracked hub resulting in leakage, and capa 2021-039 was initiated to address this issue.The capa is currently in the implementation phase and will evaluate the corrective action implementation for effectiveness to prevent a recurrence of this issue.Capa 2021-039 was initiated to address this issue and is currently in the implementation phase.The capa will evaluate the corrective action implementation for effectiveness to prevent a recurrence of this issue.
 
Event Description
Noticed fine cracks on the hub - leaking noted 12-18hrs after procedure.Picc had to be removed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
L-CATH PICC S/L 26GA (1.9F) 0.60MM X 30CM
Type of Device
L-CATH PICC
Manufacturer (Section D)
ARGON MEDICAL DEVICES
1445 flat creek rd
athens TX 75751
Manufacturer Contact
elnaz rahman
1445 flat creek rd
athens, TX 75751
9036759321
MDR Report Key14165080
MDR Text Key295899216
Report Number0001625425-2022-00987
Device Sequence Number1
Product Code FOZ
UDI-Device Identifier00886333209934
UDI-Public00886333209934
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K091670
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 05/31/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/21/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number384539
Device Catalogue Number384539
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received04/08/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-