MAUDE Adverse Event Report: SIRONA DENTAL SYSTEMS GMBH MIDWEST E PRO 1:5 HIGH SPEED CONTRA ANGLE ATTACHMENT; HANDPIECE, AIR-POWERED, DENTAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SIRONA DENTAL SYSTEMS GMBH MIDWEST E PRO 1:5 HIGH SPEED CONTRA ANGLE ATTACHMENT; HANDPIECE, AIR-POWERED, DENTAL Back to Search Results
Catalog Number 875105
Device Problem Detachment of Device or Device Component (2907)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Manufacturer Narrative
Additional serial numbers included in this report: (b)(4).11 of 11 devices were returned for evaluation.Evaluation of 1 device found it to be within specification.Evaluation of 2 devices found normal chuck wear and the turbines needed to be replaced.The devices were repaired and returned to the customers.Evaluation of 8 devices found chuck wear and lack of maintenance.The devices were cleaned of debris and the turbines were replaced.The devices were repaired and returned to the customers.
 
Event Description
This report summarizes 11 malfunction events where a midwest e pro handpiece would not hold burs.No injury resulted in any of the events.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MIDWEST E PRO 1:5 HIGH SPEED CONTRA ANGLE ATTACHMENT
Type of Device
HANDPIECE, AIR-POWERED, DENTAL
Manufacturer (Section D)
SIRONA DENTAL SYSTEMS GMBH
fabrikstrasse 31
bensheim, hessen D-646 25
GM  D-64625
Manufacturer (Section G)
SIRONA DENTAL SYSTEMS GMBH
fabrikstrasse 31
bensheim, hessen D-646 25
GM   D-64625
Manufacturer Contact
hannah seevaratnam
221 w. philadelphia st.
suite 60w
york, PA 17401
7178494593
MDR Report Key14251671
MDR Text Key290452299
Report Number9614977-2022-00028
Device Sequence Number1
Product Code EFB
Combination Product (y/n)N
PMA/PMN Number
K972436
Number of Events Reported11
Summary Report (Y/N)Y
Report Source Manufacturer
Reporter Occupation Other
Type of Report Initial
Report Date 04/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/29/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue Number875105
Patient Sequence Number1
-
-