Model Number 2227
Device Problem Leak/Splash (1354)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/10/2022
Event Type  malfunction  
Manufacturer Narrative
Product complaint # (b)(4).Additional information has been requested and received.Please provide product code for jvac reservoir? no further information is available.2179.Please provide lot number jvac reservoir => reservoir lot number is ju0540 please provide lot number for blake drain =>no further information is available.2227/unk.Is the reservoir available for return? no further information is available.Status of product return? the device has been received at sukagawa and will be shipped.Please check rmao.No further information will be provided.Additional information has been requested however not received.Attempts have been made to obtain the device, however not received to date.If further details are received at a later date a supplemental medwatch will be sent.Please clarify: is the complaint for 1 or 2 drains and 1 or 2 reservoirs? note: events reported on mw# 2210968-2022-05054, mw# 2210968-2022-05055.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Event Description
It was reported a patient underwent a spinal fusion on (b)(6) 2022 and a drain was used.The reservoir was completely swollen when these were removed in the ward.The cause was considered to be air leak, but there was also a possibility that the drain insertion site was displaced.Further details are not provided.There were no adverse consequences to the patient.
 
Manufacturer Narrative
Product complaint # (b)(4).Additional information has been requested and received.Attempts to obtain the device have been made.If further details are received at a later date a supplemental medwatch will be sent.Please clarify: is the complaint for 1 or 2 drains and 1 or 2 reservoirs? 1 drain and 1 reservoir.No further information will be provided.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Manufacturer Narrative
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Manufacturer Narrative
Product complaint # (b)(4).Additional information: d9, h6 component code: g07002 product not confirmed.H3 evaluation: product sample received for analysis.During investigation of complaint, one used sample of drain received for evaluation.One used sample of drain tied with suture near dot marking area was received for evaluation.During inspection of sample, no hole or tear found on the drain sample.Lot number of sample unknown.Reservoir not received for evaluation.Retain sample analysis could not be performed as the lot no.Is unknown.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BLAKE SI DRAIN HBLS 10FR RND W/ 1/8IN
Type of Device
CATHETER, IRRIGATION
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
DEGANIA INDIA
251, sector-6, imt manesar
gurugram
IN  
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
9083863534
MDR Report Key14885983
MDR Text Key303179394
Report Number2210968-2022-05054
Device Sequence Number1
Product Code GBX
UDI-Device Identifier10705031003552
UDI-Public10705031003552
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
CL I EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,User Facility,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup,Followup,Followup
Report Date 09/01/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/01/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number2227
Device Catalogue Number2227
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Date Manufacturer Received08/25/2022
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
-
-