MAQUET GMBH OTESUS OR TABLE COLUMN MOBILE; TABLE, OPERATING-ROOM, AC-POWERED Back to Search Results
Model Number 116001C0
Device Problems Use of Device Problem (1670); Insufficient Information (3190)
Patient Problem Skin Tears (2516)
Event Date 07/11/2022
Event Type  Injury  
Manufacturer Narrative
Additional information will be provided following the conclusion of the investigation.Device not returned to manufacturer.
 
Event Description
On (b)(6) 2022 getinge became aware of an issue with one of our tables ¿ 116001c0 - otesus or table column mobile and mayfield accessory.As it was stated, at the end of surgery, an unspecified issue occured that led to a 2 cm lateral cut at skin level, which required a suture placement.The investigated issue led to serious injury, therefore, we decided to report the issue.
 
Manufacturer Narrative
According to the reporting timeframe we would like to provide the information about current status of the issue.Please be advised that it is being investigated.Additional information will be provided following the conclusion of the investigation.The correction of b5 describe event or problem field deems required.This is based on the additional information that has been received.Previous b5 describe event or problem: on 11th july, 2022 getinge became aware of an issue with one of our tables ¿ 116001c0 - otesus or table column mobile and mayfield accessory.As it was stated, at the end of surgery, an unspecified issue occured that led to a 2 cm lateral cut at skin level, which required a suture placement.The investigated issue led to serious injury, therefore, we decided to report the issue.Corrected b5 describe event or problem: on 11th july, 2022 getinge became aware of an issue with one of our tables ¿ 116001c0 - otesus or table column mobile and mayfield accessory (doro).As it was stated, at the end of surgery, an unspecified issue occured that led to a 2 cm lateral cut at skin level, which required a suture placement.The investigated issue led to serious injury of the patient, therefore, we decided to report the issue.
 
Event Description
On 11th july, 2022 getinge became aware of an issue with one of our tables ¿ 116001c0 - otesus or table column mobile and mayfield accessory (doro).As it was stated, at the end of surgery, an unspecified issue occured that led to a 2 cm lateral cut at skin level, which required a suture placement.The investigated issue led to serious injury of the patient, therefore, we decided to report the issue.
 
Event Description
On 11th july 2022 getinge became aware of an issue with one of our tables ¿ 116001c0 - otesus or table column mobile and pro med instruments accessories (doro).According to initially provided information, at the end of the surgery, a displacement of the device occurred that led to a 2 cm lateral cut at skin level, which required a suture placement.Stitches application is considered as medical intervention to preclude permanent damage to a body structure, thus the decision that described incident led to serious injury and was reported as such.
 
Manufacturer Narrative
Getinge became aware of an issue with one of our tables ¿ 116001c0 - otesus or table column mobile and pro med instruments accessories (doro).According to initially provided information, at the end of the surgery, displacement of a device occurred that led to a 2 cm lateral cut at skin level, which required a suture placement.The investigated issue led to serious injury, therefore, we decided to report the event.At that time, it was unclear which product was directly involved with the reported incident.The affected devices have been evaluated by the getinge service technician.The operating table functions were tested and considered as up to the specification.The doro accessories manufactured by the external company were also evaluated and turned out to be defective, as no malfunction within the getinge operating table was discovered, the device was returned to the usage.The legal manufacturer of the doro accessories (pro med instruments) performed root cause analysis and evaluation of the affected neurosurgical head holder system which allow us to establish that the incident took place due to the failure of 3003-00 doro® skull clamp, which is not distributed by maquet gmbh.Several findings were indicated by pro med ( the damage coating, the helicoil /thread insert coming off due to parts being damaged and worn, too low torque screw pin pressure measurement, rough movement of the skull clamp extension assembly in the skull clamp base, teeth of a starburst out of specification and wearing of parts of the open/lock-mechanism) that were connected to frequently use, reprocessing of the device, improper use, improper or lack of maintenance activities.All of the above could have been a factor leading to the slippage incident, which is likely to have an outcome as described by the customer.Pro med also indicated that a deviation of the torque screw pin pressure measurement is, in their experience, one of the contributory factor to slippages as well.Nevertheless, it could have been avoided by user following the instruction for use, particularly the section describing how to secure the patient¿s head to the skull clamp.With the investigation performed it was concluded that upon the event occurrence, the device was being used for patient¿s treatment, thus was also directly involved with the reported incident.As no actual malfunctions were found it was considered that getinge device was up to the specification.There were no similar complaints found related to this issue investigated herein, therefore it appears to be isolated to this single occurrence, when considering this particular device range, thus the investigated issue is considered an isolated case.We currently do not have any information that would warrant further action towards the getinge device, however as per our complaint handling processes we will continue to monitor the customer experiences with the device for any future information.The correction of b1 adverse event/product problem, b5 describe event or problem and h6 medical device ¿ problem code fields deems required.This is based on the additional information that has been received and the internal evaluation.Previous b1 adverse event/product problem: adverse event & product problem.Corrected b1 adverse event/product problem: adverse event.Previous b5 describe event or problem: on 11th july, 2022 getinge became aware of an issue with one of our tables ¿ 116001c0 - otesus or table column mobile and mayfield accessory (doro).As it was stated, at the end of surgery, an unspecified issue occured that led to a 2 cm lateral cut at skin level, which required a suture placement.The investigated issue led to serious injury of the patient, therefore, we decided to report the issue.Corrected b5 describe event or problem: on 11th july 2022 getinge became aware of an issue with one of our tables ¿ 116001c0 - otesus or table column mobile and pro med instruments accessories (doro).According to initially provided information, at the end of the surgery, a displacement of the device occurred that led to a 2 cm lateral cut at skin level, which required a suture placement.Stitches application is considered as medical intervention to preclude permanent damage to a body structure, thus the decision that described incident led to serious injury and was reported as such.Previous h6 medical device ¿ problem code: insufficient information|||3190.Corrected h6 medical device ¿ problem code: use of device problem|||1670.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OTESUS OR TABLE COLUMN MOBILE
Type of Device
TABLE, OPERATING-ROOM, AC-POWERED
Manufacturer (Section D)
MAQUET GMBH
kehler strasse 31
rastatt
GM 
Manufacturer (Section G)
MAQUET GMBH
kehler strasse 31
rastatt
GM  
Manufacturer Contact
holger ullrich
kehler strasse 31
rastatt 
GM  
MDR Report Key15026677
MDR Text Key295957189
Report Number8010652-2022-00011
Device Sequence Number1
Product Code FQO
Combination Product (y/n)N
Reporter Country CodePO
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,User Facility,Company Representative
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup,Followup
Report Date 07/15/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/15/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number116001C0
Device Catalogue Number116001C0
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/28/2022
Was Device Evaluated by Manufacturer? No
Date Device Manufactured09/15/2014
Is the Device Single Use? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-