MAUDE Adverse Event Report: MEDACTA INTERNATIONAL SA GMK-HINGE 02.09.0314H FIXED TIBIAL INSERT SIZE 3/14MM; KNEE FIXED TIBIAL INSERT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDACTA INTERNATIONAL SA GMK-HINGE 02.09.0314H FIXED TIBIAL INSERT SIZE 3/14MM; KNEE FIXED TIBIAL INSERT Back to Search Results
Model Number 02.09.0314H
Device Problems Break (1069); Loose or Intermittent Connection (1371)
Patient Problem Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Date 07/07/2022
Event Type  Injury  
Event Description
Luxation of the hinge inlay, when the patient stood up from a chair.During the revision, the screw of the inlay was broken.The screw of the hinge mechanism was correctly fixated.Revision surgery performed 3 months after the primary surgery; only insert revised with a higher one (from 14 mm to 20 mm).A big laxity was observed during revision.
 
Manufacturer Narrative
Batch review performed on 11 july 2022 lot 2108837: (b)(4).Expiration date: 2026-sep-06.No anomalies found related to the problem.(b)(4).Clinical evaluation performed by medical affairs director: few weeks after implantation of a hinged tka, the system disassembles in absence of a significant trauma.The insert fixation screw is visibly broken, but this may not be the most relevant circumstance.It is very likely that the screw broke during index surgery.However, the post got out of its seat, and this may only be due to a severe laxity that probably has intervened after surgery.It is conceivable that the concomitance of the two factors, laxity and broken screw, has made disassembly a little easier, assuming that the insert has been sucked out of its seat by the femoral component.In our opinion, the root cause is severe laxity.According to report, only the insert has been replaced, which made the revision surgery not excessively traumatic for the patient and required no further bone disruption.Preliminary investigation performed by r&d manager: revision surgery of a gmk hinge implant after 3 months from primary implantation due to luxation of the tibial insert while the patient was standing up from a chair.The tibial insert looks damaged and deformed on the final portion of the central cone.The tibial insert secure screw is broken.Severe laxity was discovered and reported during the revision surgery.This laxity, progressively occurred in the patient after the primary surgery, could be the cause of this unlikely event of luxation.Laxity could also have lead to unexpected loading conditions that could have played a role also in the breakage of the insert secure screw.From preliminary investigation, there is no evidence that the event is related to a faulty device, but more likely related to a progressive patient disease.Other devices involved: batch review performed on 12 july 2022.Gmk-hinge 02.09.4003l fixed tibial tray size 3 l (k130299) lot 2009809: (b)(4).Expiration date: 2025-nov-08.(b)(4).Gmk-hinge 02.09.2604l femoral component size 4 l (k130299) lot 2003428: (b)(4).Expiration date: 2025-may-25.No anomalies found related to the problem.(b)(4).
 
Manufacturer Narrative
On 05th august 2022 we have received the pieces back.Visual inspection performed by r&d project manager.From visual inspection, we can confirm that the tibial insert looks damaged and deformed on the final portion of the central cone.The tibial insert secure screw is broken also.Severe laxity was discovered and reported during the revision surgery.The 14mm thick insert implanted in the primary surgery has been replaced by a 20mm.This laxity, progressively occurring in the patient after the primary surgery, could be the cause of this unlikely event of luxation.Laxity could also have led to unexpected loading conditions that could have also played a role in the breakage of the insert screw.From visual inspection, there is no evidence that the event is related to a faulty device, rather it is more likely related to a rapid progress of the patient's disease.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GMK-HINGE 02.09.0314H FIXED TIBIAL INSERT SIZE 3/14MM
Type of Device
KNEE FIXED TIBIAL INSERT
Manufacturer (Section D)
MEDACTA INTERNATIONAL SA
strada regina
castel san pietro, switzerland 6874
SZ  6874
Manufacturer (Section G)
MEDACTA INTERNATIONAL SA
strada regina
castel san pietro, switzerland 6874
SZ   6874
Manufacturer Contact
stefano baj
strada regina
castel san pietro, switzerland 6874
SZ   6874
MDR Report Key15147140
MDR Text Key297068208
Report Number3005180920-2022-00577
Device Sequence Number1
Product Code KRO
UDI-Device Identifier07630030825132
UDI-Public07630030825132
Combination Product (y/n)N
Reporter Country CodeSZ
PMA/PMN Number
K130299
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Company Representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date 08/02/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/02/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number02.09.0314H
Device Catalogue Number02.09.0314H
Device Lot Number2108837
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Manufacturer Received07/07/2022
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/27/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age71 YR
Patient SexFemale
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-