MAUDE Adverse Event Report: BECTON DICKINSON CARIBE LTD. BD BACTEC¿ PLUS AEROBIC/F CULTURE VIALS (PLASTIC); SYSTEM, BLOOD CULTURING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON CARIBE LTD. BD BACTEC¿ PLUS AEROBIC/F CULTURE VIALS (PLASTIC); SYSTEM, BLOOD CULTURING Back to Search Results
Model Number 442023
Device Problem Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/01/2022
Event Type  malfunction  
Manufacturer Narrative
A device evaluation and/or device history review is anticipated but is not complete.Upon completion, a supplemental report will be filed.There were multiple lot numbers reported to be involved.The information for each additional lot number is as follows: medical device lot#: 2122276.Medical device expiration date: 28-feb-2023.Device manufacture date: 02-may-2022.Medical device lot#: 2088634.Medical device expiration date: 31-jan-2023.Device manufacture date: 29-mar-2022.
 
Event Description
It was reported that while using bd bactec¿ plus aerobic/f culture vials (plastic) contamination occurred.The following information was provided by the initial reporter contaminated bottles due to isolation of paenibacillus urinals group from several bottles.
 
Manufacturer Narrative
H6.Investigation summary: catalog 442023.Batch no.2122276 & 2088634.Customer reported a paenibacillus contamination issue while using bactec product.One excels spreadsheet was received.Bd was unable to reproduce the customer¿s experience with bactec product.Retention samples were visually inspected, tested for viable contamination by sub-culturing on tsa, chocolate, sabouraud and schaedler agars plates, voltage output and gram stain.All results were satisfactory.Blood background was performed with satisfactory results.Batch history record review did not identify any evidence for which the customer submitted the complaint.A complaint history review was conducted and only the current complaint was found relating to the incident lot number and the ¿as reported¿ defect code.Complaint is unconfirmed based on retention samples and batch history record review results.Several evaluations were performed to conclude that the bio-contaminant reported, paenibacillus, did not originated from the bd manufacturing site.The autoclave process was evaluated.The moist heat autoclave is a process that uses moist heat as the lethal agent to render liquid and porous/hard goods items free from viable microorganism and relies on direct contact with saturated steam, which is water vapor in equilibrium with liquid water.The autoclave process is accomplished by the heat transfer from the steam to the load and by hydrating effect of the resultant condensate that forms due to the change in state from vapor to the lower energy liquid state.This phase change requires the transfer of the latent heat of the steam to the surroundings, thus heating the autoclave and its load.Bd cayey autoclave the products via moist heat.Initial validation had been successfully completed and the required requalification assessment has been performed accordingly maintaining the active and valid autoclaving cycle.Isolates containing the biocontamination were received from the customer.Environmental samples were evaluated from bd manufacturing site for identification of bacterial species present at different locations within the plant.The purpose of identifying these isolates was to determine if paenibacillus contamination originated from this location.After performing maldi testing, the contaminants were identified as paenibacillus species in the samples from the customer, and none of the environmental samples collected from different locations within the manufacturing plant in bd cayey were identified as paenibacillus.Finally, autoclave testing of paenibacillus species present in all samples from the customer indicated that a 15-minute autoclave cycle at 118°c is sufficient to kill vegetative cells.Bd cayey cycle is set for a higher temperature that exceeds 15 minutes.Therefore, the bio-contaminant paenibacillus likely did not originate from the bd cayey, and there is no evidence to indicate that it would it have survived the autoclaving process of bactec bottles.Product insert warnings and precautions sections states that prior to use, each vial should be examined for evidence of contamination such as cloudiness, bulging or depresses septum, or leakage.Vials showing evidence of contamination should not be used.Also prior to use, the user should examine the vial for evidence of damage or deterioration.Vials displaying turbidity, contamination, or discoloration (darkening) should not be used.A cross functional team continually monitors all product complaints for trends and determines if any additional actions are necessary beyond the current investigational process.Catalog 442023 batch no.Unknown customer reported a paenibacillus contamination issue while using bactec product.One excels spreadsheet was received.Bd was not able to perform an investigation to the retention samples since batch number is unknown.A complaint history review cannot be conducted relating to the incident lot number and the ¿as reported¿ defect code since batch number is unknown.The batch history record could not be reviewed as the lot number is unknown nonetheless batch history records are always reviewed prior to product release.Complaint is unconfirmed.Several evaluations were performed to conclude that the bio-contaminant reported, paenibacillus, did not originated from the bd manufacturing site.The autoclave process was evaluated.The moist heat autoclave is a process that uses moist heat as the lethal agent to render liquid and porous/hard goods items free from viable microorganism and relies on direct contact with saturated steam, which is water vapor in equilibrium with liquid water.The autoclave process is accomplished by the heat transfer from the steam to the load and by hydrating effect of the resultant condensate that forms due to the change in state from vapor to the lower energy liquid state.This phase change requires the transfer of the latent heat of the steam to the surroundings, thus heating the autoclave and its load.Bd cayey autoclave the products via moist heat.Initial validation had been successfully completed and the required requalification assessment has been performed accordingly maintaining the active and valid autoclaving cycle.Isolates containing the biocontamination were received from the customer.Environmental samples were evaluated from bd manufacturing site for identification of bacterial species present at different locations within the plant.The purpose of identifying these isolates was to determine if paenibacillus contamination originated from this location.After performing maldi testing, the contaminants were identified as paenibacillus species in the samples from the customer, and none of the environmental samples collected from different locations within the manufacturing plant in bd cayey were identified as paenibacillus.Finally, autoclave testing of paenibacillus species present in all samples from the customer indicated that a 15-minute autoclave cycle at 118°c is sufficient to kill vegetative cells.Bd cayey cycle is set for a higher temperature that exceeds 15 minutes.Therefore, the bio-contaminant paenibacillus likely did not originate from the bd cayey, and there is no evidence to indicate that it would it have survived the autoclaving process of bactec bottles.Product insert warnings and precautions sections states that prior to use, each vial should be examined for evidence of contamination such as cloudiness, bulging or depresses septum, or leakage.Vials showing evidence of contamination should not be used.Also prior to use, the user should examine the vial for evidence of damage or deterioration.Vials displaying turbidity, contamination, or discoloration (darkening) should not be used.A cross functional team continually monitors all product complaints for trends and determines if any additional actions are necessary beyond the current investigational process.
 
Event Description
It was reported that while using bd bactec¿ plus aerobic/f culture vials (plastic) contamination occurred.The following information was provided by the initial reporter contaminated bottles due to isolation of paenibacillus urinalis group from several bottles.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD BACTEC¿ PLUS AEROBIC/F CULTURE VIALS (PLASTIC)
Type of Device
SYSTEM, BLOOD CULTURING
Manufacturer (Section D)
BECTON DICKINSON CARIBE LTD.
vicks drive
lot no. 6
cayey PR
Manufacturer (Section G)
BECTON DICKINSON CARIBE LTD.
vicks drive
lot no. 6
cayey PR
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key15507029
MDR Text Key306261601
Report Number2647876-2022-00199
Device Sequence Number1
Product Code MDB
UDI-Device Identifier00382904420239
UDI-Public00382904420239
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K113558
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 02/15/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/29/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date02/28/2023
Device Model Number442023
Device Catalogue Number442023
Device Lot Number2122276
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received02/15/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/02/2022
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-