• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: TERUMO CARDIOVASCULAR SYSTEMS CORPORATION VIRTUOSAPH PLUS, WITH RADIAL; LAPAROSCOPE, GENERAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO CARDIOVASCULAR SYSTEMS CORPORATION VIRTUOSAPH PLUS, WITH RADIAL; LAPAROSCOPE, GENERAL Back to Search Results
Model Number VSP550EX
Device Problems Smoking (1585); Use of Device Problem (1670); Sparking (2595)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/23/2022
Event Type  Injury  
Event Description
The user facility reported to terumo cardiovascular that during vein harvesting, the lateral branches could not be blocked, and sparks were seen.As per the user facility, the operator used endoscopic vascular harvesting system to harvest the patient's saphenous vein and used the collector to block the lateral branches of the saphenous vein intraoperatively.After using the product for more than 10 minutes, it was found that the lateral branches could not be blocked and sparks were seen; therefore, the collector was hurriedly removed, and it was found that the smoldering area was charred.In the operating room, the operator turned on the power and found that the charred part of the collector would continue to emit smoke.Subsequently, the collector was replaced with another endoscopic vascular harvesting system and the lateral branches of the saphenous vein could be blocked normally.*there was a known insignificant delay in the procedure.*the product was changed out.*the surgery was completed successfully.
 
Manufacturer Narrative
Terumo has received the device for evaluation; however, the investigation has yet to be completed.Terumo plans on submitting a follow-up report when the investigation is complete and when more information becomes available.For this reason, terumo references evaluation conclusion code 11.(b)(4).
 
Manufacturer Narrative
This follow-up report is submitted to fda in accord with applicable regulations ¿ and as indicated by terumo cardiovascular systems in the initial report submitted to the fda on december 16, 2022.Upon further investigation of the reported event, the following information is new and/or changed: g6 (indication that this is a follow-up report).H2 (follow-up due to additional information and device evaluation).H6 (identification of evaluation codes 10, 11, 3331, 120, 19).Type of investigation #1: 10 - testing of actual/suspected device.Type of investigation #2: 11 - testing of device from same lot/batch retained by manufacturer.Type of investigation #3: 3331 - analysis of production records.Investigation finding: 120 - electrical problem identified.Investigation conclusions: 19 - cause traced to user.The affected sample was inspected upon receipt to confirm a burned v-cutter.The condition of the returned sample did not allow for electrical testing.A retention sample was inspected to show no anomalies with the device and a fully intact v-cutter.The sample was electrically tested.No anomalies with the device were found and all electrical tests were within specification.During the manufacturing process, all vsp550 are visually inspected and tested for functionality and performance along with inspection for v-cutter mechanism, prior to packaging.Based on review of past complaints, cracked/fractured/burnt distal end of the v-cutter most likely resulted from excessive force applied to the distal end of the v-cutter during the procedure.All available information has been placed on file in quality management for appropriate tracking, trending, and follow-up.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VIRTUOSAPH PLUS, WITH RADIAL
Type of Device
LAPAROSCOPE, GENERAL
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
125 blue ball road
elkton MD 21921
Manufacturer (Section G)
SAME
Manufacturer Contact
jamie quinlan
125 blue ball road
elkton, MD 21921
8002837866
MDR Report Key15996092
MDR Text Key305618009
Report Number1124841-2022-00190
Device Sequence Number1
Product Code GEI
UDI-Device Identifier00699753450769
UDI-Public(01)00699753450769
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K160206
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,User Facility,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 01/25/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/16/2022
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Model NumberVSP550EX
Device Catalogue NumberN/A
Device Lot Number25K
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/08/2022
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Date Manufacturer Received01/24/2023
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
VALLEYLAB FORCE FX
Patient Outcome(s) Other;
-
-