• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V. 17" (43 CM) APPX 5ML NON-DEHP EXT SET W/CLAVE®, 0.2 MICRON FILTER, CLAMP, ROTATI; STOPCOCK, I.V. SET

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V. 17" (43 CM) APPX 5ML NON-DEHP EXT SET W/CLAVE®, 0.2 MICRON FILTER, CLAMP, ROTATI; STOPCOCK, I.V. SET Back to Search Results
Model Number B9259
Device Problem Fluid/Blood Leak (1250)
Patient Problems Chemical Exposure (2570); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/01/2022
Event Type  malfunction  
Manufacturer Narrative
It is unknown if the device is available for evaluation.The device has been requested to be returned, however, it has not been received.
 
Event Description
The incident involved a 17" (43 cm) extension set with clave®, 0.2 micron filter, clamp, rotating luer on an unknown date.The reporter stated that the device keeps leaking during infusions.The patient was in the infusion chair receiving paclitaxel through the device when the device started leaking through the clave site.The infusion was immediately stopped, and a new dose was made using a new tubing set from the same lot and it also started to leak when the infusion was started.The nurse was exposed to paclitaxel on her hands.There were no holes, cuts, tears or any defect noted in the device.The set up was paclitaxel running through a plum 360 infusion pump.The 17¿ extension set with 0.2micron filter was attached to the end of the primary tubing set.It was further stated that there was patient involvement but no harm to the patient or to the healthcare provider and no delay in therapy that was critical to the patient.This is the first of two incidents.
 
Manufacturer Narrative
Seven new sets from the same lot as the affected sets were returned by the customer.Each of the new extension sets were pressure leak tested, and each met pressure leak expectations outlined in the product performance specification.The complaint of leakage was unable to be replicated or confirmed with the new extension sets returned for investigation.The actual affected samples were not returned for investigation and evaluation.A device history review for the reported lot number was performed, and the following discrepancies were identified.During physical functional testing on 30-apr-2022, quality assurance found that cavity d37 failed the crack test.Bodies were found with broken core pin in cavity b1, degraded material, shortshots and knitlines in bodies.On 17-apr-2022.Quality assurance found that cavity d34 failed the crack test.D9: product was returned to manufacturer on 09-jan-2023.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
17" (43 CM) APPX 5ML NON-DEHP EXT SET W/CLAVE®, 0.2 MICRON FILTER, CLAMP, ROTATI
Type of Device
STOPCOCK, I.V. SET
Manufacturer (Section D)
ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V.
avenida cuarzo no. 250
ensenada, b.cfa. 22790
MX  22790
Manufacturer Contact
michael visocnik
600 n. field dr.
lake forest, IL 60045
2247062300
MDR Report Key16014446
MDR Text Key308247286
Report Number9617594-2022-00330
Device Sequence Number1
Product Code FMG
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K964435
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 12/12/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/20/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberB9259
Device Catalogue NumberB9259
Device Lot Number5847625
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/16/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/01/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
PACLITAXEL, MFR UNK; PLUM360 PUMP, ICU MEDICAL; PRIMARY PLUM SET TUBING 103 INCH, ICU MEDICAL
-
-