Model Number LTF-S190-5 |
Device Problems
No Display/Image (1183); Communication or Transmission Problem (2896)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 07/28/2022 |
Event Type
malfunction
|
Manufacturer Narrative
|
The device was returned to an olympus repair facility, and an evaluation of the device was performed.During the evaluation, the customer's originally reported issue of an error code was not confirmed.The following additional findings were also noted: assorted chips, cracks, and scratches, wear of the angle wire resulting in angulation failing to meet the standard value, peeled video connector label, dirty components, damage on the lock lever preventing the bending section from being fixed firmly, and the number of broken wires in the bending tube blade exceeds the standard value.The investigation is ongoing.A supplemental report will be submitted upon completion of the investigation.
|
|
Event Description
|
An olympus representative reported on behalf of the customer, that during preparation for use of the device in an unknown therapeutic procedure, their endoeye flex deflectable videoscope exhibited an unspecified communication error immediately after connecting.The procedure was completed using a similar replacement device.There were no reports of patient or user harm associated with this event.
|
|
Manufacturer Narrative
|
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.A review of the device history record found no deviations that could have caused or contributed to the reported issue.Based on the results of the investigation, it is likely that the event was caused by breakage or disconnection of the image sensor unit due to stress of repeated use, external factors or handling, or failure of the parts mounted on the electrical circuit board such as integrated circuit chips and capacitors.The events can be detected by following the instructions for use which state: "chapter 3 preparation and inspection, section 3.8 inspection of the endoscopic system.[inspection of the endoscopic image] confirm that the wli (white light imaging) and nbi (narrow band imaging) endoscopic images are normal.1.Before inspection, wipe the objective lens using clean lint-free cloths moistened with saline solution or sterilized water.2.Observe the palm of your hand in the wli and nbi endoscopic images.3.Confirm that light is output from the endoscope¿s distal end.4.Adjust the brightness level as appropriate.5.Confirm that the wli and nbi endoscopic images are free from noise, blur, fog, or other irregularities.6.Turn the angulation control levers slowly in each direction until it stops.7.Confirm that the wli and nbi endoscopic images do not momentarily disappear or display any other irregularities." olympus will continue to monitor field performance for this device.
|
|
Search Alerts/Recalls
|
|
|