Catalog Number 6541-1-705E
Device Problems Mechanical Problem (1384); Mechanical Jam (2983)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Date 10/05/2015
Event Type  malfunction  
Manufacturer Narrative
When completed, the investigation results will be submitted in a supplemental report.
 
Event Description
Drill bit got stuck in the cutting block.
 
Manufacturer Narrative
An event regarding a drill bit got stuck in the cutting block was reported.The event was confirmed during visual and functional evaluations.Method & results: device evaluation and results: a functional analysis confirms the pin could not pass through the guide.A visual inspection showed material transfer.Also the device has been reviewed by a material subject matter expert.It was confirmed that the seizure was caused by galling.Medical records received and evaluation: not performed because patient factors did not contribute to the event.-device history review: the reported device was manufactured and accepted into final stock with no reported discrepancies.-complaint history review: there have been no other similar events reported for this manufacturing lot.Conclusions: the investigation concluded that seizure was caused by galling.No further investigation for this event is possible at this time.If additional information becomes available, this investigation will be reopened.
 
Event Description
Drill bit got stuck in the cutting block.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SIZE #5 4-IN-1 CUTTING BLOCK CAPTURED ASSY. TRIA. EXP. INSTR.
Type of Device
PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, CO
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer Contact
beverly lima
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key5195931
MDR Text Key30431967
Report Number0002249697-2015-03547
Device Sequence Number1
Product Code MBH
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K123486
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 10/05/2015
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/02/2015
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number6541-1-705E
Device Lot NumberSB9S18
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/20/2015
Is the Reporter a Health Professional? No
Date Manufacturer Received11/23/2015
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/14/2014
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other;
-
-