MAUDE Adverse Event Report: AV-TEMECULA-CT TREK CORONARY DILATATION CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

AV-TEMECULA-CT TREK CORONARY DILATATION CATHETER Back to Search Results
Catalog Number 1012407-20
Device Problems Difficult To Position (1467); Difficult to Remove (1528)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 04/26/2016
Event Type  malfunction  
Manufacturer Narrative
(b)(4). The device was received. Investigation is not yet complete. A follow up report will be submitted with all relevant information.
 
Event Description
It was reported that the trek otw dilatation catheter was advanced to the target lesion over the floppy ii guide wire. Resistance was noted; however, the dilatation catheter was able to be advanced to the target lesion and was inflated without issue. The device was deflated without issue and was noted to be fully deflated. The device was removed and resistance was noted with the guide wire. An rx trek was then advanced over the same guide wire and no resistance was noted. There was no adverse patient effect and no clinically significant delay. No additional information was provided.
 
Manufacturer Narrative
(b)(4). Evaluation summary: visual, dimensional and functional inspections were performed on the returned device. The reported resistance felt with difficulty to remove and difficulty to position issues could not be confirmed. A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event. Additionally, a review of the complaint history identified no other similar incidents from this lot. The investigation was unable to determine a conclusive cause for the reported difficulties. Based on the information reviewed, there is no indication of a product quality issue with respect to the design, manufacture or labeling of the device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameTREK CORONARY DILATATION CATHETER
Type of DeviceCORONARY DILATATION CATHETER
Manufacturer (Section D)
AV-TEMECULA-CT
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer (Section G)
EL COYOL, COSTA RICA REG# 3009031392
abbott vascular
26531 ynez road
temecula CA 92591 4628
Manufacturer Contact
connie speck
abbott vascular
26531 ynez road
temecula, CA 92591-4628
9519143996
MDR Report Key5668010
MDR Text Key45594116
Report Number2024168-2016-03274
Device Sequence Number1
Product Code LOX
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K103110
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation
Remedial Action Other
Type of Report Initial,Followup
Report Date 05/26/2016
1 Device was Involved in the Event
0 Patients were Involved in the Event:
Date FDA Received05/19/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator
Device Expiration Date02/28/2018
Device Catalogue Number1012407-20
Device Lot Number50302G1
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer04/28/2016
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received05/20/2016
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/01/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

-
-