• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SMITHS MEDICAL ASD INC. CLEO® 90 INFUSION SET SET, ADMINISTRATION, INTRAVASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITHS MEDICAL ASD INC. CLEO® 90 INFUSION SET SET, ADMINISTRATION, INTRAVASCULAR Back to Search Results
Device Problems Failure To Adhere Or Bond (1031); Detachment Of Device Component (1104); Sticking (1597)
Patient Problem Hyperglycemia (1905)
Event Date 05/04/2016
Event Type  Injury  
Manufacturer Narrative
Customer has not returned the device to the manufacturer for device evaluation. If the device becomes available and is returned and evaluated, the manufacturer will file a follow-up report detailing the results of the evaluation.
 
Event Description
It was initially reported that a cleo® 90 infusion set adhesive falls off or did not stick well over the last few months. It was then reported that the adhesive stuck to the cap and caused the site to not adhere to the patient's skin. The patient noticed the product was damaged when it was first opened. Blood glucose levels were adversely affected and reported to be over 500mg/dl. The patient used manual injections to address the high blood glucose. No permanent injury was reported. See mfr: 2183502-2016-02084, 2183502-2016-02086, 2183502-2016-02087, 2183502-2016-02088, 2183502-2016-02089, 2183502-2016-02090, 2183502-2016-02091, 2183502-2016-02092, and 2183502-2016-02093.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameCLEO® 90 INFUSION SET
Type of DeviceSET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
SMITHS MEDICAL ASD INC.
1265 grey fox rd.
st. paul MN 55112
Manufacturer (Section G)
SMITHS HEALTHCARE MFG
s.a. de c.v. ave calidad no. 4
parque industrial internaciona
tijuana, b.c. 22425
MX 22425
Manufacturer Contact
lisa perz
1265 grey fox rd.
st. paul, MN 51122
7633833074
MDR Report Key5984339
MDR Text Key55871283
Report Number2183502-2016-02085
Device Sequence Number1
Product Code FPA
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K042172
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,distributor
Reporter Occupation
Type of Report Initial,Followup
Report Date 05/11/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/28/2016
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Event Location No Information
Date Manufacturer Received08/31/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 09/28/2016 Patient Sequence Number: 1
-
-