BOSTON SCIENTIFIC - MAPLE GROVE MAVERICK2 BALLOON CATHETER CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS Back to Search Results
Model Number UNK228
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Intimal Dissection (1333)
Event Date 10/11/2016
Event Type  Injury  
Manufacturer Narrative
Device evaluated by mfr: it is indicated that the device will not be returned for evaluation. A review of the batch history, historical trending, and similar complaint trending review for the product family will be conducted. If there is any further relevant information from that review, a supplemental medwatch will be filed. (b)(4).
 
Event Description
It was reported that vessel dissection occurred. Vascular access was obtained via the right femoral artery. The 90% stenosed, 28mm in length, concentric target lesion was located in the mildly tortuous, mildly calcified, and 2. 50mm in diameter left circumflex artery. The lesion contained <
=
45 degrees bend. After a 6f 3. 5 extra back-up guide catheter was engaged and a non-bsc guide wire crossed the lesion, pre-dilation was performed with a 2. 00x12 maverick2 balloon catheter. A 2. 50x28mm promus element" plus drug-eluting stent was advanced but failed to cross the lesion. The lesion was dilated multiple times; however, it was noted that the artery got dissected. A 2. 25x40 non-bsc drug-eluting stent was then deployed and post-dilation was performed using a 2. 50x08 quantum maverick balloon catheter and the procedure was completed. No patient complications were reported and the patient's status was stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand NameMAVERICK2 BALLOON CATHETER
Type of DeviceCATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC - MAPLE GROVE
one scimed place
maple grove MN 55311
Manufacturer Contact
linda leimer
one scimed place
maple grove, MN 55311
7634941700
MDR Report Key6094295
MDR Text Key59714247
Report Number2134265-2016-10609
Device Sequence Number1
Product Code LOX
Combination Product (y/n)N
Reporter Country CodeIN
PMA/PMN Number
P860019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation
Type of Report Initial
Report Date 10/12/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/10/2016
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator
Device Model NumberUNK228
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA?
Event Location No Information
Date Manufacturer Received10/12/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial

Patient Treatment Data
Date Received: 11/10/2016 Patient Sequence Number: 1
-
-