Model Number PCO3020F
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Hematoma (1884)
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Contact office phone number: (b)(4) since the lot number was not provided, this information cannot be determined.
 
Event Description
Literature citation: citation: oommen, cn, nunes, qm, shahzad, k, smart, n, tandon, a (2016).Parietex¿ composite mesh versus dynamesh®-ipom for laparoscopic incisional and ventral hernia repair: a retrospective cohort study.Royal college of surgeons, 6, 568-573.Doi: 10.1308/rcsann.2016.0292 a total of 88 patients underwent laparacopic incisional and ventral hernia repair (livhr) between january 2008 and december 2010.Of these, 82 patients underwent laparoscopic incisional hernia repair, 5 patients had a laparoscopy-assisted procedure and 1 had conversion to open procedure; 39 patients were male and 49 were female.Median follow-up was 53.6 months (range, 40-61 months).Seventy-five patients (85.2%) presented with a primary incisional hernia, ten (11.4%) presented with a first recurrence and three (3.4%) presented with a second recurrence from their previous hernia repairs.Sixty-six patients (75%) had single defect either smaller than 4cm or between 4cm and 10cm; twenty-two patients (25%) had multiple defects.Twenty-six patients underwent livhr with a dynamesh-ipom mesh, and parietex composite mesh was used in 62 patients.The male: female ratio was 1:1.89 in the dynamesh-ipom mesh group and 1:1.07 in the parietex composite mesh group.Bmi was high in 12 patients (46%) in the dynamesh-ipom mesh group and in 35 (56.45%) in the parietex composite mesh group.In 45 patients, only protack was used to fix the mesh, whereas in 43 patients both protack and transfascial suturing were used.Incidence of conversion to open operation was 1.1%.There was no mortality in the study.Overall morbidity was 20.5%.Eight patients (12.9%) in the parietex composite mesh group developed a recurrence and four patients (6.4%) in the parietex composite mesh group (p=0.185) developed a seroma and/or haematoma.Of these, two patients developed a haematoma (this ftr is for haematoma patient #2) in the early postoperative period, which was assessed clinically and with ultrasound, and two patients were diagnosed with a seroma on ultrasound scan 6 weeks postoperatively, which settled spontaneously in follow-up and required no further intervention.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PARIETEX COMP 30X20CM W THR X1
Type of Device
MESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
SOFRADIM PRODUCTION
116 avenue du formans
trevoux
FR 
Manufacturer (Section G)
SOFRADIM PRODUCTION
116 avenue du formans
trevoux
FR  
Manufacturer Contact
sharon murphy
60 middletown ave
north haven, CT 06473
MDR Report Key6151745
MDR Text Key61785029
Report Number9615742-2016-00194
Device Sequence Number1
Product Code FTL
Combination Product (y/n)N
Reporter Country CodeUK
PMA/PMN Number
K040998
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type literature
Reporter Occupation Other
Type of Report Initial
Report Date 11/09/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/07/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberPCO3020F
Device Catalogue NumberPCO3020F
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received11/09/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age70 YR
-
-