Catalog Number 283913000
Device Problem Leak/Splash (1354)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 12/09/2016
Event Type  malfunction  
Manufacturer Narrative
(b)(4).A complaint investigation will be performed.The complaint product is not available for the investigation.A supplemental report is not anticipated unless the results of the complaint investigation identify a corrective action or additional relevant information.Should the product become available, a physical evaluation will be conducted and a supplemental report filed with the results.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Confidence complaint per complaint form: during a 1 level vertebral body augmentation procedure, the surgeon began the step of implanting cement using the confidence system.The devices were assembled on the back table and handed to the surgeon.He attached the glass vial of cement to the delivery cannula and began turning the hydraulic pump that injects the cement into the patient.Surgeon observed that hydraulic fluid appeared to be leaking at the attachment point of pump to glass vial.He stopped and tightened the connection.He tried again and there was increased pressure and then a subsequent leaking of fluid under pressure.A stream of fluid shot out at 90 degrees from the insertion cannula and extended for 4-5 feet.At that point, surgeon removed the pump, cement, and insertion cannula assembly from the patient.Another confidence kit was opened, and a new batch of cement was mixed with a new pump and glass container.Surgeon then proceeded with this new equipment and the surgery continued as planned.There was no harm to the patient other than a 2-3 minute delay while getting a new kit opened and new cement prepared.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CONFIDENCE KIT SPINAL CEMENT SYSTEM - NO NEEDLE
Type of Device
CONFIDENCE CEMENT, BONE, VERTEBROPLASTY
Manufacturer (Section D)
DEPUY SYNTHES SPINE
325 paramount drive
raynham MA 02767
Manufacturer (Section G)
DEPUY SYNTHES SPINE
325 paramount drive
raynham MA 02767
Manufacturer Contact
jason busch
325 paramount drive
raynham, MA 02767
5088808201
MDR Report Key6213641
MDR Text Key63629430
Report Number1526439-2016-10955
Device Sequence Number1
Product Code NDN
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K060300
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial
Report Date 12/09/2016
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/29/2016
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Physician
Device Catalogue Number283913000
Device Lot NumberHVKBCY
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received12/09/2016
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age61 YR
-
-